IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,598

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0667 # 04 Y:2025 04 2025 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,121 $299 n/a
SD0667 # 06 Y:2025 06 2025 ADOPT IN-HOUSE MATERIAL GENERATION $17,049 $46,406 n/a
SD0667 # 02 Y:2025 02 2025 USE BATTERY STORAGE FOR DEMAND CONTROL $260,930 $10,784 n/a
SD0667 # 01 Y:2025 01 2025 USE SOLAR HEAT TO MAKE ELECTRICTY $418,912 $524,659 n/a
SD0667 # 05 Y:2025 05 2025 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,877 $3,727 n/a
SD0667 # 03 Y:2025 03 2025 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $41,190 $8,318 n/a
SD0667 # 07 Y:2025 07 2025 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,797 $0 n/a
SJ0030 # 02 Y:2025 02 2025 USE BATTERY STORAGE FOR DEMAND CONTROL $18,627 $195,217 n/a
SJ0030 # 06 Y:2025 06 2025 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $70,368 $30,719 n/a
SJ0030 # 01 Y:2025 01 2025 USE SOLAR HEAT TO MAKE ELECTRICTY $630,866 $6,247,450 n/a
SJ0030 # 04 Y:2025 04 2025 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $15,245 $0 n/a
SJ0030 # 07 Y:2025 07 2025 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,287 $0 n/a
SJ0030 # 05 Y:2025 05 2025 TURN OFF EQUIPMENT WHEN NOT IN USE $136 $1,200 n/a
SJ0030 # 03 Y:2025 03 2025 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $15,538 $18,930 n/a
SJ0030 # 08 Y:2025 08 2025 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $663 $4,755 n/a
SF0624 # 02 Y:2024 02 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,414 $1,073 n/a
SF0624 # 05 Y:2024 05 2024 USE SOLAR HEAT TO MAKE ELECTRICTY $130,070 $760,719 n/a
SF0624 # 01 Y:2024 01 2024 TURN OFF EQUIPMENT WHEN NOT IN USE $1,603 $0 n/a
SF0624 # 03 Y:2024 03 2024 USE PHOTOCELL CONTROLS $509 $718 n/a
SF0624 # 04 Y:2024 04 2024 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $14,370 $58,959 n/a
SD0659 # 05 Y:2024 05 2024 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,955 $2,109 n/a
SD0659 # 04 Y:2024 04 2024 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $78,160 $16,180 n/a
SD0659 # 03 Y:2024 03 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $86,343 $34,702 n/a
SD0659 # 12 Y:2024 12 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $56,412 $3,345 n/a
SD0659 # 06 Y:2024 06 2024 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,742 $3,181 n/a