Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
258
matching recommendationsSIC | 301 | Tires And Inner Tubes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0085 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,936 | $7,682 | Not Implemented |
UA0085 # 03 Y:2012 | 03 | 2012 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $86,957 | $214,808 | Not Implemented |
UA0085 # 02 Y:2012 | 02 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $164,656 | $57,024 | Implemented |
UA0085 # 01 Y:2012 | 01 | 2012 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $6,264,801 | $14,443,176 | Not Implemented |
UA0085 # 10 Y:2012 | 10 | 2012 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $529,960 | $400,000 | Not Implemented |
SU0318 # 06 Y:2012 | 06 | 2012 | REDUCE VENTILATION AIR | $3,491 | $4,419 | Not Implemented |
SU0318 # 07 Y:2012 | 07 | 2012 | OPTIMIZE PLANT POWER FACTOR | $162,692 | $408,153 | Implemented |
SU0318 # 08 Y:2012 | 08 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $812 | $3,107 | Not Implemented |
SU0318 # 09 Y:2012 | 09 | 2012 | UPGRADE OBSOLETE EQUIPMENT | $211 | $795 | Implemented |
SU0318 # 01 Y:2012 | 01 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,626 | $0 | Not Implemented |
SU0318 # 02 Y:2012 | 02 | 2012 | USE SYNTHETIC LUBRICANT | $7,917 | $0 | Implemented |
SU0318 # 05 Y:2012 | 05 | 2012 | ELIMINATE/REDUCE AN OPERATION | $12,250 | $11,115 | Not Implemented |
SU0318 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $106,547 | $32,436 | Implemented |
SU0318 # 03 Y:2012 | 03 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $72 | $0 | Implemented |
MS0378 # 01 Y:2011 | 01 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $23,582 | $178,700 | Not Implemented |
MS0378 # 02 Y:2011 | 02 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $14,148 | $132,820 | Not Implemented |
LL0289 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,497 | $3,500 | Not Implemented |
LL0289 # 09 Y:2008 | 09 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $333 | $165 | Implemented |
LL0289 # 08 Y:2008 | 08 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $572 | $1,402 | Not Implemented |
LL0289 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $274,767 | $187,520 | Implemented |
LL0289 # 03 Y:2008 | 03 | 2008 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $47,583 | $1,290 | Not Implemented |
LL0289 # 02 Y:2008 | 02 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $110,300 | $3,650 | Implemented |
LL0289 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $7,830 | $1,940 | Not Implemented |
LL0289 # 04 Y:2008 | 04 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $21,390 | $11,905 | Not Implemented |
LL0289 # 07 Y:2008 | 07 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,820 | $1,710 | Not Implemented |