Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20

matching recommendations
Reset
SIC 305 Hose & Belting & Gaskets & Packing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0409 # 05 Y:1998 05 1998 $-1,436 $815 Implemented
MA0409 # 04 Y:1998 04 1998 $392 $0 Implemented
MA0409 # 03 Y:1998 03 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $157 $181 Not Implemented
MA0409 # 02 Y:1998 02 1998 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $351 $215 Not Implemented
MA0409 # 01 Y:1998 01 1998 $5,000 $650 Implemented
MA0406 # 04 Y:1998 04 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $802 $541 Implemented
MA0406 # 08 Y:1998 08 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,070 $13,540 Not Implemented
MA0406 # 07 Y:1998 07 1998 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,468 $24,000 Implemented
MA0406 # 06 Y:1998 06 1998 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $3,045 $14,790 Not Implemented
MA0406 # 05 Y:1998 05 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,955 $2,332 Not Implemented
MA0406 # 03 Y:1998 03 1998 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,323 $187 Implemented
MA0406 # 02 Y:1998 02 1998 UPGRADE CONTROLS ON COMPRESSORS $3,950 $1,785 Not Implemented
MA0406 # 01 Y:1998 01 1998 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $3,022 $200 Implemented
MA0302 # 01 Y:1994 01 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $19,139 $8,246 Not Implemented
MA0302 # 07 Y:1994 07 1994 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $5,628 $6,425 Implemented
MA0302 # 06 Y:1994 06 1994 INSTALL OCCUPANCY SENSORS $1,995 $1,466 Implemented
MA0302 # 05 Y:1994 05 1994 INSTALL SET-BACK TIMERS $3,309 $254 Implemented
MA0302 # 04 Y:1994 04 1994 BURN A LESS EXPENSIVE GRADE OF FUEL $9,629 $17,304 Implemented
MA0302 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $8,142 $25,365 Not Implemented
MA0302 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,102 $180 Implemented