Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsSIC | 305 | Hose & Belting & Gaskets & Packing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0255 # 12 Y:2000 | 12 | 2000 | CLEAR AND RENT EXISTING SPACE | $9,216 | $9,216 | Not Implemented |
IA0255 # 08 Y:2000 | 08 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $388 | $388 | Not Implemented |
IA0255 # 07 Y:2000 | 07 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $444 | $444 | Not Implemented |
IA0255 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $1,059 | $1,059 | Not Implemented |
IA0255 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $1,320 | $1,320 | Not Implemented |
IA0255 # 11 Y:2000 | 11 | 2000 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $22,880 | $22,880 | Not Implemented |
IA0255 # 10 Y:2000 | 10 | 2000 | ADD ADDITIONAL PRODUCTION SHIFT | $106,650 | $106,650 | Not Implemented |
IA0255 # 09 Y:2000 | 09 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $188 | $154 | Not Implemented |
IA0255 # 04 Y:2000 | 04 | 2000 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,735 | $1,735 | Implemented |
IA0255 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $500 | $500 | Not Implemented |
IA0255 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $675 | $675 | Implemented |
IA0255 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,653 | $3,653 | Implemented |
OD0168 # 04 Y:2000 | 04 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,521 | $345 | Not Implemented |
OD0168 # 03 Y:2000 | 03 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $319 | $250 | Implemented |
OD0168 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,584 | $4,191 | Implemented |
OD0168 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $331 | $570 | Not Implemented |
DS0165 # 05 Y:2000 | 05 | 2000 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $19,293 | $4,085 | Not Implemented |
DS0165 # 06 Y:2000 | 06 | 2000 | BURN WASTE OIL FOR HEAT | $4,893 | $3,695 | Not Implemented |
DS0165 # 07 Y:2000 | 07 | 2000 | SELL COMBUSTIBLE WASTE | $22,432 | $900 | Not Implemented |
DS0165 # 08 Y:2000 | 08 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $51,099 | $94,300 | Not Implemented |
DS0165 # 09 Y:2000 | 09 | 2000 | INSTALL SYSTEM TO COLLECT SCRAP | $6,793 | $1,634 | Not Implemented |
DS0165 # 04 Y:2000 | 04 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,267 | $42,720 | Not Implemented |
DS0165 # 03 Y:2000 | 03 | 2000 | USE OPTIMUM THICKNESS INSULATION | $494 | $275 | Not Implemented |
DS0165 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $535 | $432 | Not Implemented |
DS0165 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,045 | $12,005 | Implemented |