Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
986
matching recommendationsSIC | 306 | Fabricated Rubber Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0211 # 04 Y:1994 | 04 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,510 | $0 | Implemented |
AM0211 # 05 Y:1994 | 05 | 1994 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,050 | $2,500 | Implemented |
MO0117 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $266 | $760 | Implemented |
MO0117 # 09 Y:1994 | 09 | 1994 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,611 | $50 | Implemented |
ND0182 # 01 Y:1994 | 01 | 1994 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $95,000 | $500 | Implemented |
ND0182 # 02 Y:1994 | 02 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $68,825 | $500 | Implemented |
ND0182 # 05 Y:1994 | 05 | 1994 | OPTIMIZE PLANT POWER FACTOR | $17,888 | $18,771 | Implemented |
ND0182 # 08 Y:1994 | 08 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,800 | $320 | Implemented |
ND0182 # 09 Y:1994 | 09 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,598 | $2,403 | Implemented |
ND0183 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $17,887 | $18,770 | Implemented |
ND0183 # 05 Y:1994 | 05 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,708 | $200 | Implemented |
ND0183 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $689 | $149 | Implemented |
ND0183 # 10 Y:1994 | 10 | 1994 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $255 | $430 | Implemented |
SD0078 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,072 | $2,240 | Implemented |
SD0078 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,864 | $100 | Implemented |
SD0078 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,867 | $2,438 | Implemented |
SD0078 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $295 | $104 | Implemented |
SD0078 # 11 Y:1994 | 11 | 1994 | INSTALL OCCUPANCY SENSORS | $1,241 | $800 | Implemented |
ND0174 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,033 | $3,875 | Implemented |
ND0174 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,131 | $1,061 | Implemented |
AM0188 # 02 Y:1993 | 02 | 1993 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,390 | $2,890 | Implemented |
AM0188 # 03 Y:1993 | 03 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $2,360 | $1,040 | Implemented |
AM0188 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,500 | $400 | Implemented |
AM0188 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $595 | $1,790 | Implemented |
WI0168 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,008 | $500 | Implemented |