Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

338

matching recommendations
Reset
SIC 306 Fabricated Rubber Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0994 # 05 Y:2019 05 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,349 $10,250 Not Implemented
UD0994 # 06 Y:2019 06 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,968 $8,550 Not Implemented
UD0988 # 01 Y:2018 01 2018 TURN OFF EQUIPMENT WHEN NOT IN USE $6,505 $0 Not Implemented
UD0988 # 02 Y:2018 02 2018 USE OPTIMUM THICKNESS INSULATION $2,434 $2,072 Not Implemented
UD0988 # 03 Y:2018 03 2018 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,256 $3,172 Not Implemented
UD0988 # 04 Y:2018 04 2018 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $291 $0 Not Implemented
UD0988 # 05 Y:2018 05 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,805 $2,571 Not Implemented
UD0988 # 06 Y:2018 06 2018 INSTALL OCCUPANCY SENSORS $1,216 $595 Not Implemented
UD0988 # 07 Y:2018 07 2018 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $22,500 $20,000 Not Implemented
UD0988 # 08 Y:2018 08 2018 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,857 $11,500 Not Implemented
UD0988 # 09 Y:2018 09 2018 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,857 $6,000 Not Implemented
UD0986 # 01 Y:2018 01 2018 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $28,289 $0 Not Implemented
UD0986 # 02 Y:2018 02 2018 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $8,337 $0 Not Implemented
UD0986 # 03 Y:2018 03 2018 TURN OFF EQUIPMENT WHEN NOT IN USE $37,147 $0 Not Implemented
UD0986 # 04 Y:2018 04 2018 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $467 $0 Not Implemented
UD0986 # 05 Y:2018 05 2018 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $455 $0 Not Implemented
UD0986 # 06 Y:2018 06 2018 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,962 $2,000 Not Implemented
UD0986 # 07 Y:2018 07 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,246 $2,080 Not Implemented
UD0986 # 08 Y:2018 08 2018 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $353 $50 Not Implemented
UD0986 # 09 Y:2018 09 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $193 $500 Not Implemented
UD0986 # 10 Y:2018 10 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,539 $17,808 Not Implemented
UD0967 # 01 Y:2017 01 2017 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,073 $18,000 Not Implemented
UD0967 # 02 Y:2017 02 2017 OPERATE BOILERS ON HIGH FIRE SETTING $5,894 $27 Implemented
UD0967 # 03 Y:2017 03 2017 REPAIR OR REPLACE STEAM TRAPS $3,938 $7,676 Implemented
UD0967 # 04 Y:2017 04 2017 INSULATE FEEDWATER TANK $1,855 $4,743 Not Implemented