Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

72

matching recommendations
Reset
SIC 306 Fabricated Rubber Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0097 # 01 Y:1996 01 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,485 $120 Implemented
AR0097 # 04 Y:1996 04 1996 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $25,240 $20,000 Not Implemented
AR0097 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,496 $11,870 Implemented
AR0097 # 06 Y:1996 06 1996 OPTIMIZE PLANT POWER FACTOR $5,388 $1,000 Implemented
AR0097 # 08 Y:1996 08 1996 MINIMIZE WATER USAGE $1,489 $1,000 Implemented
AR0097 # 03 Y:1996 03 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,972 $1,745 Not Implemented
AR0097 # 05 Y:1996 05 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $929 $0 Implemented
AR0097 # 07 Y:1996 07 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,027 $4,900 Implemented
AR0091 # 11 Y:1996 11 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $39,367 $8,000 Implemented
AR0091 # 12 Y:1996 12 1996 MODIFY MATERIAL APPLICATION METHODS $45,625 $0 Implemented
AR0091 # 10 Y:1996 10 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $152,084 $1,000 Implemented
AR0091 # 09 Y:1996 09 1996 USE RADIANT HEATER FOR SPOT HEATING $5,749 $2,000 Not Implemented
AR0091 # 08 Y:1996 08 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,839 $1,000 Implemented
AR0091 # 01 Y:1996 01 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,763 $1,784 Not Implemented
AR0091 # 07 Y:1996 07 1996 REPAIR AND ELIMINATE STEAM LEAKS $1,747 $170 Implemented
AR0091 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,261 $400 Not Implemented
AR0091 # 05 Y:1996 05 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $365 $0 Implemented
AR0091 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $544 $583 Implemented
AR0091 # 03 Y:1996 03 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,074 $190 Implemented
AR0091 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $890 $442 Not Implemented
MO0179 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,921 $1,311 Implemented
MO0179 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,159 $5,364 Not Implemented
MO0179 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,967 $9,063 Implemented
MO0179 # 05 Y:1996 05 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,057 $0 Implemented
MO0179 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $95 $0 Not Implemented