Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
93
matching recommendationsSIC | 306 | Fabricated Rubber Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0561 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,924 | $75,720 | Implemented |
MA0561 # 02 Y:2004 | 02 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,006 | $25,500 | Implemented |
MA0561 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,624 | $4,550 | Implemented |
MA0561 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,473 | $2,750 | Implemented |
MA0561 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $3,147 | $735 | Implemented |
MA0561 # 04 Y:2004 | 04 | 2004 | REDUCE VENTILATION AIR | $6,815 | $4,530 | Implemented |
WI0480 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,595 | $150 | Not Implemented |
WI0480 # 08 Y:2004 | 08 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $554 | $0 | Implemented |
WI0480 # 10 Y:2004 | 10 | 2004 | INSULATE BARE EQUIPMENT | $364 | $160 | Implemented |
WI0480 # 09 Y:2004 | 09 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $372 | $600 | Not Implemented |
WI0480 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,263 | $39,140 | Not Implemented |
WI0480 # 07 Y:2004 | 07 | 2004 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $634 | $1,500 | Implemented |
WI0480 # 11 Y:2004 | 11 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $137 | $0 | Implemented |
WI0480 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,496 | $640 | Not Implemented |
WI0480 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,086 | $5,500 | Not Implemented |
WI0480 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $1,779 | $600 | Not Implemented |
WI0480 # 02 Y:2004 | 02 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,606 | $500 | Implemented |
WV0299 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,651 | $16,100 | Implemented |
WV0299 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $10,724 | $2,060 | Implemented |
WV0299 # 04 Y:2004 | 04 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,783 | $1,937 | Implemented |
WV0299 # 16 Y:2004 | 16 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $672 | $600 | Implemented |
WV0299 # 03 Y:2004 | 03 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,725 | $1,000 | Implemented |
WV0299 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,363 | $300 | Implemented |
WV0299 # 07 Y:2004 | 07 | 2004 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,364 | $40 | Not Implemented |
WV0299 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,152 | $160 | Implemented |