Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 306 | Fabricated Rubber Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0402 # 01 Y:2011 | 01 | 2011 | USE PHOTOCELL CONTROLS | $1,438 | $3,737 | Not Implemented |
SF0402 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $2,857 | $10,811 | Not Implemented |
SF0402 # 03 Y:2011 | 03 | 2011 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $5,402 | $23,288 | Not Implemented |
SF0402 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,789 | $29,916 | Not Implemented |
SF0402 # 05 Y:2011 | 05 | 2011 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $766 | $4,483 | Not Implemented |
SF0402 # 06 Y:2011 | 06 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,637 | $11,070 | Not Implemented |
WV0434 # 01 Y:2011 | 01 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $23,833 | $46,000 | Not Implemented |
WV0434 # 12 Y:2011 | 12 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $164 | $455 | Not Implemented |
WV0434 # 11 Y:2011 | 11 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $814 | $0 | Not Implemented |
WV0434 # 10 Y:2011 | 10 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,304 | $3,000 | Not Implemented |
WV0434 # 09 Y:2011 | 09 | 2011 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,304 | $2,105 | Not Implemented |
WV0434 # 08 Y:2011 | 08 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,596 | $9,940 | Not Implemented |
WV0434 # 07 Y:2011 | 07 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,623 | $1,025 | Implemented |
WV0434 # 06 Y:2011 | 06 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $2,898 | $810 | Implemented |
WV0434 # 05 Y:2011 | 05 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,984 | $4,000 | Implemented |
WV0434 # 04 Y:2011 | 04 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,577 | $7,840 | Implemented |
WV0434 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,335 | $14,967 | Implemented |
WV0434 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,864 | $1,234 | Implemented |
MI0205 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,634 | $38,332 | Not Implemented |
MI0205 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,412 | $1,320 | Not Implemented |
MI0205 # 05 Y:2011 | 05 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,114 | $2,500 | Implemented |
MI0205 # 04 Y:2011 | 04 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,662 | $17,186 | Not Implemented |
MI0205 # 03 Y:2011 | 03 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $4,980 | $18,280 | Not Implemented |
MI0205 # 02 Y:2011 | 02 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,973 | $1,984 | Not Implemented |