Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsSIC | 3069 | Fabricated Rubber Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0218 # 01 Y:2001 | 01 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $535 | $188 | Not Implemented |
WV0149 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,271 | $0 | Implemented |
WV0149 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $886 | $98 | Not Implemented |
WV0149 # 03 Y:1998 | 03 | 1998 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $16,316 | $0 | Implemented |
WV0149 # 04 Y:1998 | 04 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $53,897 | $0 | Not Implemented |
WV0149 # 05 Y:1998 | 05 | 1998 | BURN A LESS EXPENSIVE GRADE OF FUEL | $4,200 | $7,200 | Not Implemented |
WV0149 # 06 Y:1998 | 06 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,988 | $3,005 | Not Implemented |
WV0149 # 07 Y:1998 | 07 | 1998 | PAY UTILITY BILLS ON TIME | $1,820 | $0 | Implemented |
WV0149 # 08 Y:1998 | 08 | 1998 | INSULATE BARE EQUIPMENT | $1,667 | $1,120 | Implemented |
WV0149 # 09 Y:1998 | 09 | 1998 | INSULATE BARE EQUIPMENT | $411 | $320 | Implemented |
WV0149 # 10 Y:1998 | 10 | 1998 | COVER OPEN TANKS | $1,515 | $4,656 | Not Implemented |
WV0149 # 11 Y:1998 | 11 | 1998 | OPTIMIZE PLANT POWER FACTOR | $4,342 | $14,610 | Not Implemented |
WV0149 # 12 Y:1998 | 12 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $118 | $5,030 | Implemented |
WV0149 # 13 Y:1998 | 13 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,715 | $3,272 | Implemented |
WV0149 # 14 Y:1998 | 14 | 1998 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,046 | $1,000 | Not Implemented |
WV0149 # 15 Y:1998 | 15 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,365 | $960 | Implemented |
WV0149 # 16 Y:1998 | 16 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $3,840 | $42 | Implemented |
WV0149 # 17 Y:1998 | 17 | 1998 | USE EVAPORATION TO CONCENTRATE MATERIAL | $1,020 | $1,068 | Not Implemented |
WV0149 # 18 Y:1998 | 18 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $54,000 | $0 | Implemented |