Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,537
matching recommendationsSIC | 3069 | Fabricated Rubber Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0649 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,456 | $6,189 | Not Implemented |
GT0649 # 08 Y:1998 | 08 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $3,046 | $0 | Not Implemented |
GT0649 # 09 Y:1998 | 09 | 1998 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $4,100 | $1,000 | Not Implemented |
MA0429 # 01 Y:1998 | 01 | 1998 | IMPROVE SPACE COMFORT CONDITIONING | $14,812 | $19,107 | Not Implemented |
MA0429 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,695 | $5,302 | Implemented |
MA0429 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $268 | $0 | Implemented |
MA0429 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $412 | $60 | Implemented |
MA0429 # 05 Y:1998 | 05 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $269 | $66 | Not Implemented |
MA0429 # 06 Y:1998 | 06 | 1998 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $268 | $130 | Not Implemented |
WV0154 # 01 Y:1998 | 01 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,075 | $2,580 | Not Implemented |
WV0154 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $16,667 | $9,432 | Not Implemented |
WV0154 # 03 Y:1998 | 03 | 1998 | INSULATE BARE EQUIPMENT | $4,282 | $5,130 | Not Implemented |
WV0154 # 04 Y:1998 | 04 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $322 | $482 | Not Implemented |
WV0154 # 05 Y:1998 | 05 | 1998 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $162 | $550 | Not Implemented |
WV0154 # 06 Y:1998 | 06 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $142 | $220 | Not Implemented |
WV0154 # 07 Y:1998 | 07 | 1998 | RECOVER AND REUSE COOLING WATER | $670 | $1,525 | Not Implemented |
WV0154 # 08 Y:1998 | 08 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,940 | $550 | Not Implemented |
WV0154 # 09 Y:1998 | 09 | 1998 | CLEAR AND RENT EXISTING SPACE | $180,000 | $4,000 | Not Implemented |
WV0149 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $886 | $98 | Not Implemented |
WV0149 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,271 | $0 | Implemented |
WV0149 # 03 Y:1998 | 03 | 1998 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $16,316 | $0 | Implemented |
WV0149 # 04 Y:1998 | 04 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $53,897 | $0 | Not Implemented |
WV0149 # 05 Y:1998 | 05 | 1998 | BURN A LESS EXPENSIVE GRADE OF FUEL | $4,200 | $7,200 | Not Implemented |
WV0149 # 06 Y:1998 | 06 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,988 | $3,005 | Not Implemented |
WV0149 # 07 Y:1998 | 07 | 1998 | PAY UTILITY BILLS ON TIME | $1,820 | $0 | Implemented |