Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

896

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0639 # 03 Y:2013 03 2013 PAY UTILITY BILLS ON TIME $7,089 $0 Implemented
AM0639 # 04 Y:2013 04 2013 CLEAN CONDENSER TUBES $6,020 $7,540 Implemented
AM0639 # 05 Y:2013 05 2013 OPTIMIZE PLANT POWER FACTOR $5,960 $13,780 Not Implemented
AM0639 # 06 Y:2013 06 2013 USE SYNTHETIC LUBRICANT $4,190 $0 Implemented
AM0639 # 07 Y:2013 07 2013 INSTALL OCCUPANCY SENSORS $1,440 $1,840 Not Implemented
OK0841 # 01 Y:2013 01 2013 RECOVER WASTE HEAT FROM EQUIPMENT $44,134 $43,500 Not Implemented
OK0841 # 02 Y:2013 02 2013 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $68,923 $4,000 Not Implemented
OK0841 # 03 Y:2013 03 2013 INSULATE BARE EQUIPMENT $15,201 $4,500 Not Implemented
OK0841 # 04 Y:2013 04 2013 INSTALL OCCUPANCY SENSORS $693 $4,051 Implemented
OK0841 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $151 $228 Not Implemented
OK0841 # 06 Y:2013 06 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $40,107 $74,800 Not Implemented
OK0841 # 07 Y:2013 07 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,217 $4,000 Implemented
OK0841 # 08 Y:2013 08 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,111 $1,134 Implemented
OK0841 # 09 Y:2013 09 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $33,063 $21,269 Not Implemented
OK0841 # 10 Y:2013 10 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $36,370 $33,509 Not Implemented
OK0841 # 11 Y:2013 11 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,860 $5,760 Not Implemented
OK0841 # 12 Y:2013 12 2013 INSTALL SET-BACK TIMERS $1,913 $1,520 Not Implemented
OK0841 # 13 Y:2013 13 2013 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT $3,085 $14,817 Implemented
AM0631 # 01 Y:2013 01 2013 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $166,700 $10,000 Not Implemented
AM0631 # 02 Y:2013 02 2013 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $10,080 $0 Not Implemented
AM0631 # 03 Y:2013 03 2013 OPTIMIZE PLANT POWER FACTOR $9,560 $14,980 Not Implemented
AM0631 # 04 Y:2013 04 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,290 $500 Not Implemented
AM0624 # 01 Y:2012 01 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $415 $350 Implemented
AM0624 # 02 Y:2012 02 2012 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $360 $0 Implemented
AM0624 # 03 Y:2012 03 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $12,100 $0 Implemented