IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

411

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0066 # 05 Y:1982 05 1982 OPTIMIZE PLANT POWER FACTOR $1,504 $1,520 Not Implemented
OK0066 # 06 Y:1982 06 1982 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $56 $114 Not Implemented
OK0066 # 07 Y:1982 07 1982 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $5,173 $24,000 Not Implemented
OK0066 # 08 Y:1982 08 1982 INSTALL TIMERS AND/OR THERMOSTATS $69 $296 Implemented
OK0066 # 09 Y:1982 09 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $263 $95 Not Implemented
OK0066 # 10 Y:1982 10 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $36 $38 Not Implemented
OK0053 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $54 $38 Not Implemented
OK0053 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,297 $470 Not Implemented
OK0053 # 03 Y:1982 03 1982 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,819 $4,800 Not Implemented
OK0053 # 04 Y:1982 04 1982 INSULATE BARE EQUIPMENT $2,044 $4,000 Not Implemented
OK0053 # 05 Y:1982 05 1982 OPTIMIZE PLANT POWER FACTOR $11,988 $8,348 Not Implemented
OK0053 # 06 Y:1982 06 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $346 $132 Not Implemented
OK0053 # 07 Y:1982 07 1982 USE UTILITY CONTROLLED POWER MANAGEMENT $902 $0 Not Implemented
OK0055 # 01 Y:1982 01 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,052 $58 Not Implemented
OK0055 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $3,457 $800 Not Implemented
OK0055 # 03 Y:1982 03 1982 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,901 $4,000 Not Implemented
OK0055 # 04 Y:1982 04 1982 REDUCE GLAZED AREAS IN BUILDINGS $2,354 $3,036 Not Implemented
OK0037 # 01 Y:1982 01 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,854 $300 Not Implemented
OK0037 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,647 $552 Not Implemented
OK0037 # 03 Y:1982 03 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $749 $1,484 Not Implemented
OK0037 # 04 Y:1982 04 1982 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $43 $125 Not Implemented
OK0054 # 01 Y:1982 01 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,115 $140 Not Implemented
OK0054 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $5,398 $100 Not Implemented
OK0054 # 03 Y:1982 03 1982 INSTALL TIMERS AND/OR THERMOSTATS $644 $100 Not Implemented
OK0054 # 04 Y:1982 04 1982 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,457 $0 Not Implemented