Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
113
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0118 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $10,122 | $8,800 | Implemented |
UA0118 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,871 | $70,925 | Implemented |
UA0118 # 04 Y:2014 | 04 | 2014 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $56,812 | $0 | Not Implemented |
UA0118 # 03 Y:2014 | 03 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,870 | $100 | Not Implemented |
UA0118 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $57,584 | $9,695 | Implemented |
UA0118 # 01 Y:2014 | 01 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $64,943 | $3,600 | Not Implemented |
UA0117 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,244 | $3,515 | Not Implemented |
UA0117 # 07 Y:2014 | 07 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,033 | $1,900 | Not Implemented |
UA0117 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,971 | $800 | Not Implemented |
UA0117 # 05 Y:2014 | 05 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,571 | $7,675 | Not Implemented |
UA0117 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $4,219 | $1,139 | Not Implemented |
UA0117 # 03 Y:2014 | 03 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $14,760 | $21,000 | Implemented |
UA0117 # 01 Y:2014 | 01 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $116,327 | $120 | Not Implemented |
UA0108 # 08 Y:2013 | 08 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $2,099 | $152 | Implemented |
UA0108 # 07 Y:2013 | 07 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,872 | $1,425 | Not Implemented |
UA0108 # 06 Y:2013 | 06 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,603 | $2,591 | Implemented |
UA0108 # 05 Y:2013 | 05 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,894 | $490 | Implemented |
UA0108 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,157 | $800 | Implemented |
UA0108 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $4,734 | $858 | Implemented |
UA0108 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,880 | $1,900 | Implemented |
UA0108 # 04 Y:2013 | 04 | 2013 | USE PHOTOCELL CONTROLS | $145 | $607 | Not Implemented |
UA0080 # 06 Y:2012 | 06 | 2012 | USE PHOTOCELL CONTROLS | $632 | $270 | Implemented |
UA0080 # 04 Y:2012 | 04 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $981 | $364 | Implemented |
UA0080 # 03 Y:2012 | 03 | 2012 | INSULATE BARE EQUIPMENT | $15,904 | $7,093 | Not Implemented |
UA0080 # 01 Y:2012 | 01 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $18,321 | $480 | Implemented |