Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,307

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0659 # 03 Y:2002 03 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,958 $28,264 Not Implemented
UD0659 # 04 Y:2002 04 2002 RECOVER WASTE HEAT FROM EQUIPMENT $5,878 $3,000 Not Implemented
UD0659 # 05 Y:2002 05 2002 OPTIMIZE PLANT POWER FACTOR $5,400 $6,750 Implemented
UD0659 # 06 Y:2002 06 2002 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $5,040 $1,300 Not Implemented
UD0659 # 07 Y:2002 07 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,633 $0 Not Implemented
UD0659 # 08 Y:2002 08 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,464 $1,000 Implemented
UD0659 # 09 Y:2002 09 2002 USE RADIANT HEATER FOR SPOT HEATING $2,424 $6,000 Not Implemented
UD0659 # 10 Y:2002 10 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,776 $120 Implemented
UD0659 # 11 Y:2002 11 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,450 $1,985 Not Implemented
UD0659 # 12 Y:2002 12 2002 INSULATE BARE EQUIPMENT $1,196 $519 Not Implemented
UD0659 # 13 Y:2002 13 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $906 $1,785 Not Implemented
UD0659 # 14 Y:2002 14 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $417 $168 Not Implemented
UD0659 # 15 Y:2002 15 2002 DISCONNECT BALLASTS $392 $35 Implemented
UD0657 # 01 Y:2002 01 2002 DEVELOP STANDARD OPERATING PROCEDURES $1,600,000 $339,333 Implemented
UD0657 # 02 Y:2002 02 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $186,552 $719,845 Not Implemented
UD0657 # 03 Y:2002 03 2002 USE RADIANT HEATER FOR SPOT HEATING $25,129 $10,500 Not Implemented
UD0657 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,470 $0 Implemented
UD0657 # 05 Y:2002 05 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,040 $9,089 Not Implemented
UD0657 # 06 Y:2002 06 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $894 $1,000 Not Implemented
UD0657 # 07 Y:2002 07 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $805 $97 Not Implemented
UD0653 # 01 Y:2002 01 2002 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $1,356,000 $500,000 Implemented
UD0653 # 02 Y:2002 02 2002 DEVELOP STANDARD OPERATING PROCEDURES $222,000 $0 Implemented
UD0653 # 03 Y:2002 03 2002 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $32,655 $36,000 Not Implemented
UD0653 # 04 Y:2002 04 2002 INSULATE BARE EQUIPMENT $6,181 $733 Implemented
UD0653 # 05 Y:2002 05 2002 RECOVER WASTE HEAT FROM EQUIPMENT $4,155 $2,000 Not Implemented