Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
13,535
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0105 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $856 | $3,000 | Implemented |
SF0105 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $905 | $1,082 | Implemented |
SF0105 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $532 | $1,560 | Not Implemented |
SF0105 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,020 | $5,900 | Implemented |
SF0105 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,782 | $1,960 | Not Implemented |
SF0105 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $651 | $600 | Implemented |
SF0105 # 07 Y:1996 | 07 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $809 | $250 | Implemented |
CO0378 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,430 | $15,373 | Implemented |
CO0378 # 02 Y:1996 | 02 | 1996 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $4,590 | $630 | Implemented |
CO0378 # 03 Y:1996 | 03 | 1996 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $1,940 | $1,790 | Not Implemented |
CO0378 # 04 Y:1996 | 04 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,770 | $3,010 | Not Implemented |
CO0378 # 05 Y:1996 | 05 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $500 | $0 | Implemented |
CO0378 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $360 | $160 | Implemented |
CO0378 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $330 | $150 | Implemented |
CO0378 # 08 Y:1996 | 08 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $44 | $58 | Implemented |
CO0378 # 09 Y:1996 | 09 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $200 | $160 | Not Implemented |
AM0285 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $49,000 | $70,000 | Implemented |
AM0285 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $30,300 | $47,880 | Not Implemented |
AM0285 # 03 Y:1996 | 03 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,830 | $5,660 | Implemented |
AM0285 # 04 Y:1996 | 04 | 1996 | SHIP HYDRAULIC OIL TO SECONDARY FUEL PROGRAM | $465 | $0 | Not Implemented |
AM0285 # 05 Y:1996 | 05 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $340 | $0 | Not Implemented |
UL0170 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $6,726 | $7,330 | Implemented |
UL0170 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $937 | $636 | Implemented |
UL0170 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $199 | $20 | Not Implemented |
UL0170 # 04 Y:1996 | 04 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,360 | $200 | Implemented |