Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
576
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0291 # 06 Y:2005 | 06 | 2005 | USE SYNTHETIC LUBRICANT | $6,678 | $1,000 | Not Implemented |
BD0291 # 07 Y:2005 | 07 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,582 | $11,250 | Not Implemented |
BD0291 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,134 | $2,200 | Not Implemented |
BD0291 # 09 Y:2005 | 09 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,677 | $0 | Not Implemented |
BD0291 # 10 Y:2005 | 10 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $2,257 | $2,500 | Not Implemented |
BD0291 # 11 Y:2005 | 11 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,162 | $2,000 | Not Implemented |
BD0291 # 12 Y:2005 | 12 | 2005 | INSTALL OCCUPANCY SENSORS | $1,620 | $2,000 | Not Implemented |
BD0291 # 13 Y:2005 | 13 | 2005 | PAY BILLS ON TIME TO AVOID LATE FEES | $3,744 | $2,500 | Not Implemented |
BD0291 # 14 Y:2005 | 14 | 2005 | AUTOMATE PAYROLL SYSTEM | $2,950 | $0 | Not Implemented |
IC0099 # 01 Y:2005 | 01 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,719 | $35,000 | Not Implemented |
IC0099 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,085 | $66,591 | Not Implemented |
IC0099 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $246 | $0 | Implemented |
IC0099 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,577 | $1,200 | Implemented |
IC0099 # 05 Y:2005 | 05 | 2005 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $6,852 | $1,520 | Implemented |
IC0099 # 06 Y:2005 | 06 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $671 | $48 | Not Implemented |
IC0099 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $92 | $364 | Not Implemented |
IC0099 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $531 | $1,121 | Not Implemented |
IC0085 # 01 Y:2004 | 01 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $25,215 | $2,944 | Implemented |
IC0085 # 02 Y:2004 | 02 | 2004 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,699 | $0 | Implemented |
IC0085 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,310 | $588 | Implemented |
IC0085 # 04 Y:2004 | 04 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $2,624 | $456 | Not Implemented |
IC0085 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $36,746 | $18,000 | Implemented |
IC0085 # 06 Y:2004 | 06 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,123 | $13,680 | Not Implemented |
IC0085 # 07 Y:2004 | 07 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,640 | $138,438 | Implemented |
IC0085 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $2,016 | $5,841 | Not Implemented |