Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
492
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0159 # 05 Y:1996 | 05 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $32,996 | $11,835 | Not Implemented |
SD0159 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $9,126 | $1,230 | Implemented |
SD0159 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $38,040 | $1,000 | Implemented |
SF0094 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $183 | $653 | Implemented |
SF0094 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,146 | $12,480 | Implemented |
SF0094 # 03 Y:1996 | 03 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,762 | $1,975 | Not Implemented |
SF0094 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $4,296 | $8,880 | Not Implemented |
SF0094 # 05 Y:1996 | 05 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $10,370 | $500 | Not Implemented |
NV0059 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,658 | $2,000 | n/a |
NV0059 # 02 Y:1996 | 02 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $814 | $60 | n/a |
NV0059 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $511 | $56 | n/a |
NV0059 # 04 Y:1996 | 04 | 1996 | UPGRADE OBSOLETE EQUIPMENT | $11,766 | $33,000 | n/a |
NV0059 # 05 Y:1996 | 05 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,340 | $0 | n/a |
WI0275 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,083 | $1,400 | Not Implemented |
WI0275 # 02 Y:1996 | 02 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,633 | $14,000 | Not Implemented |
WI0275 # 03 Y:1996 | 03 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,271 | $3,200 | Not Implemented |
WI0275 # 04 Y:1996 | 04 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $588 | $450 | Not Implemented |
WI0275 # 05 Y:1996 | 05 | 1996 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,984 | $0 | Not Implemented |
WI0275 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,750 | $3,184 | Not Implemented |
WI0275 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $1,013 | $600 | Implemented |
WI0275 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $591 | Not Implemented |
WI0275 # 09 Y:1996 | 09 | 1996 | USE AUTOMATIC FLOW CONTROL | $676 | $200 | Implemented |
WI0275 # 10 Y:1996 | 10 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $653 | $200 | Implemented |
AR0085 # 01 Y:1996 | 01 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,787 | $1,670 | Implemented |
AR0085 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $508 | $130 | Implemented |