Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1996 |
Principal Product | Injection molded plastic products |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 65,000 |
Annual Production | 3,000,000 Pounds |
Production Hrs. Annual | 6,120 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $219,489 | 2,810,961 | kWh | $0.08 |
Electricity Demand | $86,659 | 7,166 | kW-months/year | $12.09 |
Electricity Fees | $1,040 | - | $ | - |
Natural Gas | $18,508 | 5,438 | MMBtu | $3.40 |
TOTAL ENERGY COSTS | $325,696 | |||
RECOMMENDED SAVINGS* | $20,995 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,342 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $6,083 Cost: $1,400 |
$4,016 | 90,563 | $3,378 | 266 | $(-1,311) | (-386) | - | - |
$4,016 90,563 kWh |
$3,378 266 kW-months/year |
$(-1,311) (-386) MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $4,633 Cost: $14,000 |
$3,261 | 73,564 | $1,372 | 108 | - | - | - | - |
$3,261 73,564 kWh |
$1,372 108 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $3,271 Cost: $3,200 |
- | - | - | - | $3,271 | 997 | - | - |
- - kWh |
- - kW-months/year |
$3,271 997 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $588 Cost: $450 |
- | - | - | - | $588 | 173 | - | - |
- - kWh |
- - kW-months/year |
$588 173 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $1,984 Cost: - |
- | - | $1,984 | 168 | - | - | - | - |
- - kWh |
$1,984 168 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,750 Cost: $3,184 |
$1,288 | 18,464 | $462 | 36 | - | - | - | - |
$1,288 18,464 kWh |
$462 36 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,013 Cost: $600 |
$1,013 | 22,860 | - | - | - | - | - | - |
$1,013 22,860 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $344 Cost: $591 |
$161 | 3,517 | $183 | 14 | - | - | - | - |
$161 3,517 kWh |
$183 14 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.1194 USE AUTOMATIC FLOW CONTROL |
Savings: $676 Cost: $200 |
- | - | - | - | - | - | $676 | 173,280 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$676 173,280 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $653 Cost: $200 |
- | - | - | - | $653 | 192 | - | - |
- - kWh |
- - kW-months/year |
$653 192 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,995 Cost: $23,825 |
$9,739 | 208,968 | $7,379 | 592 | $3,201 | 976 | $676 | 173,280 | $9,739 208,968 kWh |
$7,379 592 kW-months/year |
$3,201 976 MMBtu |
$676 173,280 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,342 Cost: $1,000 |
$1,013 | 22,860 | - | - | $653 | 192 | $676 | 173,280 | $1,013 22,860 kWh |
- - kW-months/year |
$653 192 MMBtu |
$676 173,280 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |