Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
884
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0806 # 07 Y:2011 | 07 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,222 | $870 | Not Implemented |
OK0806 # 08 Y:2011 | 08 | 2011 | INSULATE BARE EQUIPMENT | $6,859 | $2,964 | Not Implemented |
OK0806 # 09 Y:2011 | 09 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,676 | $7,130 | Not Implemented |
AM0589 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $21,960 | $90 | Implemented |
AM0589 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,080 | $23 | Implemented |
AM0589 # 03 Y:2011 | 03 | 2011 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,251 | $0 | Implemented |
AM0589 # 04 Y:2011 | 04 | 2011 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,230 | $370 | Implemented |
AM0589 # 05 Y:2011 | 05 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,885 | $0 | Not Implemented |
AM0589 # 06 Y:2011 | 06 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,575 | $0 | Implemented |
AM0589 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $205 | $225 | Implemented |
AM0589 # 08 Y:2011 | 08 | 2011 | PAY UTILITY BILLS ON TIME | $236 | $0 | Implemented |
NC0412 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $140,256 | $442,314 | Implemented |
NC0412 # 02 Y:2010 | 02 | 2010 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $25,289 | $50 | Implemented |
NC0412 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,233 | $100 | Implemented |
NC0412 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $2,841 | $4,995 | Implemented |
NC0412 # 05 Y:2010 | 05 | 2010 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $7,153 | $15,100 | Implemented |
NC0412 # 06 Y:2010 | 06 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,349 | $13,200 | Not Implemented |
NC0412 # 07 Y:2010 | 07 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,402 | $1,200 | Implemented |
NC0412 # 08 Y:2010 | 08 | 2010 | ADVERTISE PRODUCT OR SERVICE | $1,000,000 | $2,000,000 | Not Implemented |
NC0412 # 09 Y:2010 | 09 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $91,232 | $255,000 | Not Implemented |
GT0873 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,353 | $0 | Implemented |
GT0873 # 02 Y:2010 | 02 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,144 | $4,600 | Not Implemented |
GT0873 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,825 | $19,768 | Not Implemented |
GT0873 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $3,777 | $10,640 | Implemented |
GT0873 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $816 | $4,400 | Implemented |