Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
864
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0219 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $20,164 | $53 | Not Implemented |
UF0219 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,814 | $2,600 | Implemented |
UF0219 # 04 Y:1999 | 04 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,141 | $0 | Not Implemented |
UF0219 # 05 Y:1999 | 05 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,800 | $0 | Not Implemented |
UF0219 # 06 Y:1999 | 06 | 1999 | $820 | $1,200 | Implemented | |
UF0219 # 07 Y:1999 | 07 | 1999 | $7,893 | $0 | Not Implemented | |
MA0433 # 01 Y:1999 | 01 | 1999 | $18,033 | $25,200 | Not Implemented | |
MA0433 # 02 Y:1999 | 02 | 1999 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,704 | $5,262 | Not Implemented |
MA0433 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,317 | $3,950 | Implemented |
MA0433 # 04 Y:1999 | 04 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,414 | $0 | Not Implemented |
MA0433 # 05 Y:1999 | 05 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,135 | $0 | Not Implemented |
MA0433 # 06 Y:1999 | 06 | 1999 | $2,000 | $700 | Not Implemented | |
MA0433 # 07 Y:1999 | 07 | 1999 | $6,150 | $1,200 | Not Implemented | |
AS0243 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,432 | $3,754 | Not Implemented |
AS0243 # 02 Y:1999 | 02 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,379 | $225 | Not Implemented |
AS0243 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,369 | $5,320 | Not Implemented |
AS0243 # 04 Y:1999 | 04 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,180 | $5,434 | Not Implemented |
AS0243 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $7,800 | $80 | Implemented |
AS0243 # 06 Y:1999 | 06 | 1999 | $13,172 | $5,400 | Not Implemented | |
AS0243 # 07 Y:1999 | 07 | 1999 | $142,183 | $196,000 | Not Implemented | |
KU0508 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,850 | $5,030 | Implemented |
KU0508 # 02 Y:1998 | 02 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,900 | $7,180 | Implemented |
KU0508 # 03 Y:1998 | 03 | 1998 | INSTALL OCCUPANCY SENSORS | $470 | $350 | Implemented |
KU0508 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $440 | $100 | Implemented |
KU0508 # 05 Y:1998 | 05 | 1998 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $530 | $1,500 | Not Implemented |