Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
104
matching recommendationsSIC | 3086 | Plastics Foam Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0286 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $2,292 | $0 | Implemented |
SD0286 # 08 Y:2002 | 08 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $262,070 | $1,200,000 | Not Implemented |
SD0286 # 09 Y:2002 | 09 | 2002 | USE EVAPORATION TO CONCENTRATE MATERIAL | $540 | $300 | Implemented |
SD0286 # 10 Y:2002 | 10 | 2002 | USE EVAPORATION TO CONCENTRATE MATERIAL | $122,879 | $200,000 | Not Implemented |
SD0286 # 11 Y:2002 | 11 | 2002 | INSTALL EQUIPMENT TO MOVE PRODUCT | $9,000 | $3,500 | Implemented |
SD0286 # 12 Y:2002 | 12 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $28,610 | $35,000 | Not Implemented |
SD0286 # 13 Y:2002 | 13 | 2002 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $20,964 | $25,000 | Not Implemented |
SD0286 # 14 Y:2002 | 14 | 2002 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $3,348 | $7,000 | Implemented |
SD0286 # 15 Y:2002 | 15 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $4,380 | $3,000 | Implemented |
SD0286 # 16 Y:2002 | 16 | 2002 | CHANGE OPERATING CONDITIONS | $2,333 | $0 | Implemented |
SD0223 # 01 Y:1999 | 01 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,581 | $7,800 | Not Implemented |
SD0223 # 02 Y:1999 | 02 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,521 | $3,930 | Implemented |
SD0223 # 03 Y:1999 | 03 | 1999 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $73,012 | $62,000 | Not Implemented |
SD0223 # 04 Y:1999 | 04 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $17,647 | $45,000 | Not Implemented |
SD0223 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $10,800 | $0 | Implemented |
SD0223 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,900 | $9,000 | Not Implemented |
SD0223 # 07 Y:1999 | 07 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $43,030 | $54,952 | Not Implemented |
SD0223 # 08 Y:1999 | 08 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $118,672 | $67,000 | Not Implemented |
SF0164 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,886 | $1,618 | Not Implemented |
SF0164 # 02 Y:1999 | 02 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $278 | $125 | Not Implemented |
SF0164 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $1,460 | $896 | Not Implemented |
SF0164 # 04 Y:1999 | 04 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,384 | $981 | Not Implemented |
SF0164 # 05 Y:1999 | 05 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,137 | $4,800 | Not Implemented |
SF0164 # 06 Y:1999 | 06 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,717 | $2,424 | Not Implemented |
SF0164 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,244 | $4,080 | Not Implemented |