Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

29

matching recommendations
Reset
SIC 3086 Plastics Foam Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0415 # 09 Y:2008 09 2008 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $49,178 $49,400 Not Implemented
UF0415 # 08 Y:2008 08 2008 INSTALL COMMON HEADER ON COMPRESSORS $6,290 $550 Not Implemented
UF0415 # 07 Y:2008 07 2008 DEVELOP A REPAIR/REPLACE POLICY $648 $0 Implemented
UF0415 # 06 Y:2008 06 2008 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $27,511 $182,894 Not Implemented
UF0415 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $666 $0 Implemented
UF0415 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $34,736 $30,084 Implemented
UF0415 # 03 Y:2008 03 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,271 $400 Not Implemented
UF0415 # 02 Y:2008 02 2008 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $19,825 $20,000 Not Implemented
UF0415 # 01 Y:2008 01 2008 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $662 $300 Not Implemented
DL0014 # 01 Y:2008 01 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $3,600 $0 Implemented
DL0014 # 02 Y:2008 02 2008 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $470 $635 Not Implemented
DL0014 # 03 Y:2008 03 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $2,173 $4,200 Not Implemented
DL0014 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,481 $12,133 Not Implemented
DL0014 # 05 Y:2008 05 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,500 $15,000 Not Implemented
DL0014 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,200 $20,000 Not Implemented
DL0012 # 02 Y:2008 02 2008 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $19,600 $23,900 Not Implemented
DL0012 # 06 Y:2008 06 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,902 $11,000 Not Implemented
DL0012 # 05 Y:2008 05 2008 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $3,154 $0 Not Implemented
DL0012 # 04 Y:2008 04 2008 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $6,766 $16,500 Not Implemented
DL0012 # 03 Y:2008 03 2008 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $5,988 $146 Not Implemented
DL0012 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $27,593 $26,675 Implemented
IA0420 # 05 Y:2008 05 2008 INSTALL OCCUPANCY SENSORS $881 $560 Not Implemented
IA0420 # 06 Y:2008 06 2008 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,156 $600 Not Implemented
IA0420 # 07 Y:2008 07 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $14,440 $2,400 Not Implemented
IA0420 # 08 Y:2008 08 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,130 $2,824 Not Implemented