Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
202
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0292 # 07 Y:2024 | 07 | 2024 | INSULATE BARE EQUIPMENT | $19,216 | $10,388 | Implemented |
IC0292 # 04 Y:2024 | 04 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $130,075 | $1,202,972 | Not Implemented |
IC0292 # 05 Y:2024 | 05 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,838 | $0 | Not Implemented |
IC0292 # 02 Y:2024 | 02 | 2024 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,518 | $9,738 | Implemented |
IC0292 # 01 Y:2024 | 01 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $434 | $0 | Implemented |
IC0292 # 06 Y:2024 | 06 | 2024 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,786 | $0 | Implemented |
IC0292 # 08 Y:2024 | 08 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $20,681 | $163,749 | Not Implemented |
IC0292 # 03 Y:2024 | 03 | 2024 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,811 | $17,313 | Not Implemented |
IA0527 # 02 Y:2014 | 02 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $10,226 | $100 | Not Implemented |
IA0527 # 07 Y:2014 | 07 | 2014 | INSTALL SPECTRAL REFLECTORS / DELAMP | $646 | $210 | Not Implemented |
IA0527 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $577 | $1,116 | Not Implemented |
IA0527 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,843 | $365 | Implemented |
IA0527 # 04 Y:2014 | 04 | 2014 | USE PHOTOCELL CONTROLS | $1,490 | $810 | Not Implemented |
IA0527 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,000 | $2,939 | Not Implemented |
IA0527 # 01 Y:2014 | 01 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,002 | $11,806 | Not Implemented |
IA0527 # 08 Y:2014 | 08 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $274 | $75 | Not Implemented |
IA0515 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $848 | $402 | Not Implemented |
IA0515 # 03 Y:2014 | 03 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,894 | $14,469 | Implemented |
IA0515 # 01 Y:2014 | 01 | 2014 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $21,416 | $3,325 | Implemented |
IA0515 # 06 Y:2014 | 06 | 2014 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $5,119 | $140,200 | Not Implemented |
IA0515 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,610 | $392 | Implemented |
IA0515 # 02 Y:2014 | 02 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,176 | $380 | Implemented |
IA0491 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $2,096 | $2,626 | Implemented |
IA0491 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,631 | $600 | Implemented |
IA0491 # 06 Y:2012 | 06 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $363 | $175 | Implemented |