IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

562

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0500 # 03 Y:2006 03 2006 INSTALL AUTOMATIC PACKING EQUIPMENT $40,600 $50,000 Not Implemented
AM0500 # 04 Y:2006 04 2006 INSTALL AUTOMATIC PACKING EQUIPMENT $30,500 $272 Not Implemented
AM0500 # 05 Y:2006 05 2006 OPTIMIZE PLANT POWER FACTOR $6,900 $6,900 Implemented
AM0500 # 06 Y:2006 06 2006 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $4,520 $0 Not Implemented
AM0500 # 07 Y:2006 07 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $1,800 $0 Implemented
AM0500 # 08 Y:2006 08 2006 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $430 $0 Implemented
AM0500 # 09 Y:2006 09 2006 USE SYNTHETIC LUBRICANT $422 $0 Not Implemented
AM0500 # 10 Y:2006 10 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $343 $192 Implemented
TA0104 # 01 Y:2005 01 2005 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $7,070 $0 Implemented
TA0104 # 02 Y:2005 02 2005 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $22,990 $0 Implemented
TA0104 # 03 Y:2005 03 2005 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,020 $1,880 Not Implemented
TA0104 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,491 $241 Implemented
TA0104 # 05 Y:2005 05 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,785 $1,444 Implemented
TA0104 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $6,461 $244 Implemented
TA0103 # 01 Y:2005 01 2005 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $12,460 $8,170 Not Implemented
TA0103 # 02 Y:2005 02 2005 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $1,365 $2,620 Implemented
TA0103 # 03 Y:2005 03 2005 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $14,113 $0 Implemented
TA0103 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,990 $0 Implemented
TA0103 # 05 Y:2005 05 2005 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $700 $1,070 Implemented
TA0099 # 01 Y:2005 01 2005 INSULATE BARE EQUIPMENT $26,045 $2,079 Not Implemented
TA0099 # 02 Y:2005 02 2005 FILTER AND REUSE HYDRAULIC OIL $25,230 $6,200 Not Implemented
TA0099 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,435 $11,735 Not Implemented
TA0099 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,725 $55 Not Implemented
TA0099 # 05 Y:2005 05 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,090 $600 Not Implemented
TA0099 # 06 Y:2005 06 2005 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,170 $1,575 Not Implemented