Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,727
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0309 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,366 | $1,000 | Not Implemented |
ND0309 # 06 Y:1998 | 06 | 1998 | CONVERT TO AQUEOUS CLEANING SYSTEM | $848 | $100 | Implemented |
ND0309 # 07 Y:1998 | 07 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $478 | $0 | Implemented |
ND0309 # 08 Y:1998 | 08 | 1998 | INSTALL OCCUPANCY SENSORS | $458 | $800 | Not Implemented |
ND0309 # 09 Y:1998 | 09 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $131 | $60 | Implemented |
ND0309 # 10 Y:1998 | 10 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $101 | $250 | Not Implemented |
ND0309 # 11 Y:1998 | 11 | 1998 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $20 | $20 | Implemented |
UL0204 # 01 Y:1998 | 01 | 1998 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $54,505 | $140,960 | Not Implemented |
UL0204 # 02 Y:1998 | 02 | 1998 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $162,300 | $0 | Not Implemented |
UL0204 # 03 Y:1998 | 03 | 1998 | ELIMINATE/REDUCE AN OPERATION | $5,360 | $0 | Not Implemented |
MS0121 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,571 | $469 | Implemented |
MS0121 # 02 Y:1998 | 02 | 1998 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $917 | $0 | Implemented |
MS0121 # 03 Y:1998 | 03 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,114 | $4,819 | Not Implemented |
MS0121 # 04 Y:1998 | 04 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $217 | $708 | Implemented |
MS0121 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,877 | $4,762 | Not Implemented |
MS0121 # 06 Y:1998 | 06 | 1998 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,336 | $1,471 | Not Implemented |
MS0121 # 07 Y:1998 | 07 | 1998 | INSULATE BARE EQUIPMENT | $2,615 | $104 | Implemented |
MS0121 # 08 Y:1998 | 08 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $39,411 | $0 | Implemented |
MS0121 # 09 Y:1998 | 09 | 1998 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $150,000 | $100,000 | Implemented |
OR0329 # 01 Y:1998 | 01 | 1998 | MODIFY CURRENT INCENTIVE PROGRAM | $21,200 | $22,600 | Not Implemented |
OR0329 # 02 Y:1998 | 02 | 1998 | DEVELOP STANDARD OPERATING PROCEDURES | $1,950 | $1,140 | Implemented |
OR0329 # 03 Y:1998 | 03 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $2,982 | $1,000 | Not Implemented |
OR0329 # 04 Y:1998 | 04 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $22,670 | $239,200 | Not Implemented |
ND0316 # 01 Y:1998 | 01 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,390 | $46,000 | Not Implemented |
ND0316 # 02 Y:1998 | 02 | 1998 | AIR CONDITION ONLY SPACE NECESSARY | $8,600 | $37,000 | Not Implemented |