Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

294

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0538 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $548 $274 Not Implemented
CO0538 # 05 Y:2004 05 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,150 $2,790 Implemented
CO0538 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $536 $390 Implemented
CO0538 # 03 Y:2004 03 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $4,530 $500 Implemented
CO0538 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,300 $170 Implemented
CO0538 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,780 $13,490 n/a
CO0502 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $360 $30 Implemented
CO0502 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $830 $0 Not Implemented
CO0502 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,060 $1,050 Implemented
CO0502 # 02 Y:2002 02 2002 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,090 $6,200 Not Implemented
CO0502 # 01 Y:2002 01 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,320 $53,800 Not Implemented
CO0497 # 03 Y:2001 03 2001 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,470 $7,170 Implemented
CO0497 # 01 Y:2001 01 2001 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,250 $12,000 n/a
CO0497 # 02 Y:2001 02 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,610 $22,110 Implemented
CO0497 # 04 Y:2001 04 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,230 $440 Implemented
CO0497 # 05 Y:2001 05 2001 INSULATE BARE EQUIPMENT $770 $430 Implemented
CO0497 # 06 Y:2001 06 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $90 $0 Implemented
CO0497 # 07 Y:2001 07 2001 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $87,600 $6,280 Implemented
CO0499 # 01 Y:2002 01 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $26,240 $84,240 Not Implemented
CO0499 # 06 Y:2002 06 2002 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $105,600 $120,000 Not Implemented
CO0499 # 05 Y:2002 05 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190 $0 Implemented
CO0497 # 08 Y:2001 08 2001 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $10,760 $250 Implemented
CO0499 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $610 $260 Implemented
CO0499 # 04 Y:2002 04 2002 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $540 $900 Implemented
CO0499 # 02 Y:2002 02 2002 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,480 $7,000 Implemented