Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

217

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0156 # 12 Y:1985 12 1985 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $11,431 $0 Not Implemented
OK0120 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $397 $89 Not Implemented
OK0120 # 02 Y:1984 02 1984 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $91 $0 Implemented
OK0120 # 03 Y:1984 03 1984 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $335 $0 Implemented
OK0112 # 01 Y:1983 01 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $823 $1,750 Not Implemented
OK0112 # 02 Y:1983 02 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $860 $1,238 Not Implemented
OK0112 # 03 Y:1983 03 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $420 $300 Not Implemented
OK0112 # 04 Y:1983 04 1983 INSTALL / REPAIR INSULATION ON STEAM LINES $358 $262 Not Implemented
OK0066 # 01 Y:1982 01 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,410 $9,010 Not Implemented
OK0066 # 02 Y:1982 02 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $973 $633 Implemented
OK0066 # 03 Y:1982 03 1982 USE DEMAND CONTROLLER OR LOAD SHEDDER $718 $433 Not Implemented
OK0066 # 04 Y:1982 04 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,042 $0 Not Implemented
OK0066 # 05 Y:1982 05 1982 OPTIMIZE PLANT POWER FACTOR $1,504 $1,520 Not Implemented
OK0066 # 06 Y:1982 06 1982 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $56 $114 Not Implemented
OK0066 # 07 Y:1982 07 1982 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $5,173 $24,000 Not Implemented
OK0066 # 08 Y:1982 08 1982 INSTALL TIMERS AND/OR THERMOSTATS $69 $296 Implemented
OK0066 # 09 Y:1982 09 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $263 $95 Not Implemented
OK0066 # 10 Y:1982 10 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $36 $38 Not Implemented
OK0053 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $54 $38 Not Implemented
OK0053 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,297 $470 Not Implemented
OK0053 # 03 Y:1982 03 1982 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,819 $4,800 Not Implemented
OK0053 # 04 Y:1982 04 1982 INSULATE BARE EQUIPMENT $2,044 $4,000 Not Implemented
OK0053 # 05 Y:1982 05 1982 OPTIMIZE PLANT POWER FACTOR $11,988 $8,348 Not Implemented
OK0053 # 06 Y:1982 06 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $346 $132 Not Implemented
OK0053 # 07 Y:1982 07 1982 USE UTILITY CONTROLLED POWER MANAGEMENT $902 $0 Not Implemented