Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
291
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0059 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,658 | $2,000 | n/a |
NV0059 # 02 Y:1996 | 02 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $814 | $60 | n/a |
NV0059 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $511 | $56 | n/a |
NV0059 # 04 Y:1996 | 04 | 1996 | UPGRADE OBSOLETE EQUIPMENT | $11,766 | $33,000 | n/a |
NV0059 # 05 Y:1996 | 05 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,340 | $0 | n/a |
AR0085 # 01 Y:1996 | 01 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,787 | $1,670 | Implemented |
AR0085 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $508 | $130 | Implemented |
AR0085 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $94 | $80 | Implemented |
AR0085 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,710 | $6,520 | Implemented |
AR0085 # 05 Y:1996 | 05 | 1996 | INSULATE BARE EQUIPMENT | $3,093 | $569 | Implemented |
WI0275 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,083 | $1,400 | Not Implemented |
WI0275 # 02 Y:1996 | 02 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,633 | $14,000 | Not Implemented |
WI0275 # 03 Y:1996 | 03 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,271 | $3,200 | Not Implemented |
AR0085 # 06 Y:1996 | 06 | 1996 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $122 | $0 | Not Implemented |
AR0085 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,760 | $5,000 | Implemented |
WI0275 # 10 Y:1996 | 10 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $653 | $200 | Implemented |
WI0275 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $591 | Not Implemented |
WI0275 # 09 Y:1996 | 09 | 1996 | USE AUTOMATIC FLOW CONTROL | $676 | $200 | Implemented |
WI0275 # 04 Y:1996 | 04 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $588 | $450 | Not Implemented |
WI0275 # 05 Y:1996 | 05 | 1996 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,984 | $0 | Not Implemented |
WI0275 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,750 | $3,184 | Not Implemented |
WI0275 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $1,013 | $600 | Implemented |
BD0061 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $53,987 | $7,000 | Not Implemented |
UF0153 # 03 Y:1996 | 03 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $27,649 | $23,150 | Implemented |
UF0153 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,550 | $25,740 | Not Implemented |