Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
327
matching recommendationsSIC | 314 | Footwear, Except Rubber |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0360 # 01 Y:1989 | 01 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $10,266 | $24,045 | Not Implemented |
TN0360 # 02 Y:1989 | 02 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $4,620 | $1,150 | Implemented |
TN0360 # 03 Y:1989 | 03 | 1989 | INSULATE BARE EQUIPMENT | $4,865 | $1,211 | Not Implemented |
TN0360 # 04 Y:1989 | 04 | 1989 | USE MINIMUM STEAM OPERATING PRESSURE | $1,135 | $0 | Implemented |
TN0360 # 05 Y:1989 | 05 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,550 | $600 | Implemented |
TN0360 # 06 Y:1989 | 06 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,685 | $1,700 | Implemented |
TN0360 # 07 Y:1989 | 07 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $703 | $0 | Implemented |
TN0360 # 08 Y:1989 | 08 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,128 | $900 | Implemented |
TN0292 # 01 Y:1986 | 01 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,140 | $12,500 | Not Implemented |
TN0292 # 02 Y:1986 | 02 | 1986 | INSTALL SET-BACK TIMERS | $1,198 | $0 | Implemented |
TN0292 # 03 Y:1986 | 03 | 1986 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $947 | $2,960 | Not Implemented |
TN0292 # 04 Y:1986 | 04 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $206 | $175 | Implemented |
TN0292 # 05 Y:1986 | 05 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $152 | $75 | Implemented |
UD0100 # 01 Y:1983 | 01 | 1983 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $3,030 | $1,000 | Implemented |
UD0100 # 02 Y:1983 | 02 | 1983 | INSTALL STORM WINDOWS AND DOORS | $5,208 | $2,000 | Implemented |
UD0100 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,279 | $4,668 | Implemented |
UD0100 # 04 Y:1983 | 04 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $7,768 | $2,000 | Implemented |
UD0100 # 05 Y:1983 | 05 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $263 | $1,590 | Not Implemented |
GT0198 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,736 | $2,860 | Implemented |
GT0198 # 02 Y:1983 | 02 | 1983 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,500 | $1,000 | Implemented |
GT0198 # 03 Y:1983 | 03 | 1983 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,522 | $4,064 | Implemented |
GT0198 # 04 Y:1983 | 04 | 1983 | INSTALL SET-BACK TIMERS | $11,778 | $0 | Implemented |
UD0032 # 01 Y:1982 | 01 | 1982 | KEEP LAMPS AND REFLECTORS CLEAN | $223 | $5 | Implemented |
UD0032 # 02 Y:1982 | 02 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $617 | $3,206 | Implemented |
UD0032 # 03 Y:1982 | 03 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $349 | $1,141 | Implemented |