IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

327

matching recommendations
Reset
SIC 314 Footwear, Except Rubber
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0121 # 06 Y:1997 06 1997 REDUCE VENTILATION AIR $4,459 $12,500 Implemented
AR0121 # 07 Y:1997 07 1997 INSTALL OCCUPANCY SENSORS $320 $738 Not Implemented
AR0121 # 08 Y:1997 08 1997 RECOVER AND REUSE COOLING WATER $2,438 $4,200 Implemented
AR0121 # 09 Y:1997 09 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,410 $0 Implemented
AR0121 # 10 Y:1997 10 1997 $16,725 $12,600 Not Implemented
AR0121 # 11 Y:1997 11 1997 $30,333 $15,000 Not Implemented
MO0188 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,043 $5,437 Implemented
MO0188 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $191 $0 Not Implemented
MO0188 # 03 Y:1996 03 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $484 $0 Implemented
MO0188 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $872 $360 Not Implemented
MO0188 # 05 Y:1996 05 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,156 $120 Not Implemented
MO0188 # 06 Y:1996 06 1996 USE SYNTHETIC LUBRICANT $202 $416 Not Implemented
MO0188 # 07 Y:1996 07 1996 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,950 $0 Not Implemented
ME0181 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,271 $27,695 Implemented
ME0181 # 02 Y:1996 02 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,099 $632 Implemented
ME0181 # 03 Y:1996 03 1996 INSULATE BARE EQUIPMENT $1,990 $1,130 Implemented
ME0181 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,653 $750 Implemented
ME0181 # 05 Y:1996 05 1996 CLOSE OFF UNNEEDED STEAM LINES $2,370 $200 Implemented
ME0181 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,212 $1,000 Implemented
ME0181 # 07 Y:1996 07 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $1,069 $0 Implemented
ME0181 # 08 Y:1996 08 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $923 $400 Implemented
ME0181 # 09 Y:1996 09 1996 INSULATE BARE EQUIPMENT $596 $305 Not Implemented
ME0181 # 10 Y:1996 10 1996 PAY UTILITY BILLS ON TIME $1,608 $0 Implemented
ME0179 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,031 $47,372 Implemented
ME0179 # 02 Y:1996 02 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,629 $2,864 Not Implemented