Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
75
matching recommendationsSIC | 3149 | Footwear, Except Rubber, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0142 # 08 Y:2019 | 08 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $351 | $1,115 | Implemented |
WM0142 # 05 Y:2019 | 05 | 2019 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,795 | $2,700 | Implemented |
WM0142 # 03 Y:2019 | 03 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,679 | $6,540 | Implemented |
WM0142 # 10 Y:2019 | 10 | 2019 | USE PHOTOCELL CONTROLS | $103 | $201 | Not Implemented |
WM0142 # 09 Y:2019 | 09 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $258 | $1,370 | Not Implemented |
WM0142 # 01 Y:2019 | 01 | 2019 | INSTALL OCCUPANCY SENSORS | $19,750 | $28,500 | Not Implemented |
WM0142 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $619 | $1,160 | Implemented |
WM0142 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,469 | $3,500 | Implemented |
WM0142 # 02 Y:2019 | 02 | 2019 | USE RADIANT HEATER FOR SPOT HEATING | $7,329 | $9,450 | Implemented |
WM0142 # 07 Y:2019 | 07 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $418 | $750 | Not Implemented |
TT0195 # 01 Y:2017 | 01 | 2017 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $36,700 | $4,000 | Not Implemented |
TT0195 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,092 | $3,050 | Implemented |
TT0195 # 03 Y:2017 | 03 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,404 | $6,000 | Not Implemented |
TT0195 # 04 Y:2017 | 04 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,211 | $25 | Implemented |
TT0195 # 06 Y:2017 | 06 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $665 | $750 | Not Implemented |
TT0195 # 05 Y:2017 | 05 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,190 | $3,450 | Not Implemented |
TT0195 # 07 Y:2017 | 07 | 2017 | APPLY FOR INVESTMENT INCENTIVES | $98 | $20 | Implemented |
GT0630 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,900 | $20,800 | Implemented |
GT0630 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,370 | $500 | Implemented |
GT0630 # 03 Y:1997 | 03 | 1997 | DISCONNECT BALLASTS | $153 | $280 | Implemented |
GT0630 # 04 Y:1997 | 04 | 1997 | COMBINE UTILITY METERS | $2,920 | $0 | Not Implemented |
GT0630 # 05 Y:1997 | 05 | 1997 | OPTIMIZE PLANT POWER FACTOR | $6,200 | $3,900 | Not Implemented |
GT0630 # 06 Y:1997 | 06 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,540 | $6,700 | Implemented |
GT0630 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,580 | $0 | Implemented |
GT0630 # 08 Y:1997 | 08 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $800 | $0 | Not Implemented |