Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
330
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0094 # 05 Y:1996 | 05 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,367 | $4,500 | Not Implemented |
WV0094 # 06 Y:1996 | 06 | 1996 | USE PLASTIC PALLETS INSTEAD OF WOOD | $11,520 | $5,784 | Not Implemented |
WV0094 # 07 Y:1996 | 07 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $13,272 | $7,000 | Implemented |
WV0082 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,516 | $26,600 | Implemented |
WV0082 # 02 Y:1996 | 02 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,819 | $1,280 | Implemented |
WV0082 # 03 Y:1996 | 03 | 1996 | USE SYNTHETIC LUBRICANT | $433 | $395 | Implemented |
WV0082 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $907 | $95 | Implemented |
WV0082 # 05 Y:1996 | 05 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,486 | $1,467 | Not Implemented |
WV0082 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES | $50,374 | $5,000 | Not Implemented |
WV0082 # 07 Y:1996 | 07 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,200 | $4,980 | Not Implemented |
WV0079 # 01 Y:1996 | 01 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,997 | $1,030 | Implemented |
WV0079 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $438 | $11,920 | Implemented |
WV0079 # 03 Y:1996 | 03 | 1996 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $19,407 | $65,000 | Not Implemented |
WV0079 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $106 | $8 | Implemented |
WV0079 # 05 Y:1996 | 05 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,721 | $5,000 | Implemented |
WV0079 # 06 Y:1996 | 06 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $13,672 | $3,560 | Not Implemented |
WV0079 # 07 Y:1996 | 07 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,228 | $0 | Implemented |
WV0079 # 08 Y:1996 | 08 | 1996 | MINIMIZE WATER USAGE | $9,875 | $1,532 | Implemented |
WV0069 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,242 | $1,587 | Implemented |
WV0069 # 02 Y:1995 | 02 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $329 | $1,280 | Not Implemented |
WV0069 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $415 | $192 | Not Implemented |
WV0069 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $878 | $40 | Implemented |
WV0069 # 05 Y:1995 | 05 | 1995 | USE SYNTHETIC LUBRICANT | $1,217 | $1,300 | Implemented |
WV0069 # 06 Y:1995 | 06 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,834 | $5,068 | Not Implemented |
WV0069 # 07 Y:1995 | 07 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $842 | $200 | Implemented |