Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
45
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0365 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,995 | $3,000 | Implemented |
IA0365 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $1,148 | $1,001 | Not Implemented |
IA0365 # 05 Y:2005 | 05 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $628 | $1,600 | Implemented |
IA0365 # 06 Y:2005 | 06 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $1,000,000 | $152,672 | Implemented |
IA0365 # 07 Y:2005 | 07 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $11,495 | $14,000 | Not Implemented |
IA0365 # 08 Y:2005 | 08 | 2005 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $21,000 | $7,216 | Implemented |
KU0345 # 04 Y:1991 | 04 | 1991 | REDUCE VENTILATION AIR | $1,505 | $200 | Implemented |
KU0345 # 01 Y:1991 | 01 | 1991 | REDUCE OR ELIMINATE WASTE | $71,400 | $0 | Not Implemented |
KU0345 # 02 Y:1991 | 02 | 1991 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $3,220 | $1,500 | Implemented |
KU0345 # 03 Y:1991 | 03 | 1991 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,154 | $2,200 | Implemented |
KU0345 # 10 Y:1991 | 10 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,528 | $1,000 | Implemented |
KU0345 # 05 Y:1991 | 05 | 1991 | USE OPTIMUM THICKNESS INSULATION | $374 | $600 | Implemented |
KU0345 # 06 Y:1991 | 06 | 1991 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,461 | $5,300 | Implemented |
KU0345 # 07 Y:1991 | 07 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $618 | $950 | Implemented |
KU0345 # 08 Y:1991 | 08 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $715 | $300 | Implemented |
KU0345 # 09 Y:1991 | 09 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $536 | $60 | Implemented |
KU0345 # 14 Y:1991 | 14 | 1991 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $968 | $0 | Not Implemented |
KU0345 # 13 Y:1991 | 13 | 1991 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $439 | $1,429 | Implemented |
KU0345 # 12 Y:1991 | 12 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $169 | $0 | Implemented |
KU0345 # 11 Y:1991 | 11 | 1991 | INSTALL SET-BACK TIMERS | $796 | $950 | Implemented |