Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,698
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0129 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $76,534 | $250,000 | Not Implemented |
UD0129 # 02 Y:1984 | 02 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $723 | $601 | Not Implemented |
UD0129 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,376 | $2,096 | Not Implemented |
TN0198 # 01 Y:1984 | 01 | 1984 | INSULATE BARE EQUIPMENT | $3,850 | $2,583 | Implemented |
TN0198 # 02 Y:1984 | 02 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $442 | $589 | Implemented |
TN0198 # 03 Y:1984 | 03 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $257 | $0 | Implemented |
TN0198 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $0 | $108 | Implemented |
TN0198 # 05 Y:1984 | 05 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $168 | $183 | Implemented |
TN0188 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $4,400 | $3,000 | Not Implemented |
TN0188 # 02 Y:1983 | 02 | 1983 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,900 | $100 | Not Implemented |
TN0188 # 03 Y:1983 | 03 | 1983 | OPTIMIZE PLANT POWER FACTOR | $500 | $4,800 | Not Implemented |
TN0194 # 01 Y:1983 | 01 | 1983 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $1,460 | $17 | Not Implemented |
TN0194 # 02 Y:1983 | 02 | 1983 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $410 | $0 | Not Implemented |
TN0194 # 03 Y:1983 | 03 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $180 | $0 | Not Implemented |
TN0194 # 04 Y:1983 | 04 | 1983 | INSTALL SET-BACK TIMERS | $70 | $824 | Not Implemented |
TN0194 # 05 Y:1983 | 05 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $148 | $850 | Not Implemented |
TN0194 # 06 Y:1983 | 06 | 1983 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $260 | $296 | Not Implemented |
UD0107 # 01 Y:1983 | 01 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $1,233 | $750 | Not Implemented |
UD0107 # 02 Y:1983 | 02 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,281 | $487 | Implemented |
UD0107 # 03 Y:1983 | 03 | 1983 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $873 | $600 | Not Implemented |
UD0107 # 04 Y:1983 | 04 | 1983 | INSTALL STORM WINDOWS AND DOORS | $668 | $182 | Not Implemented |
TN0184 # 01 Y:1983 | 01 | 1983 | IMPROVE LUBRICATION PRACTICES | $1,670 | $4,200 | Not Implemented |
TN0184 # 02 Y:1983 | 02 | 1983 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,420 | $0 | Not Implemented |
TN0185 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $260 | $3,200 | Not Implemented |
TN0185 # 02 Y:1983 | 02 | 1983 | REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH | $360 | $0 | Not Implemented |