Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
228
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0666 # 09 Y:1999 | 09 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $52,500 | $45,000 | Not Implemented |
GT0666 # 10 Y:1999 | 10 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,800 | $0 | Implemented |
GT0665 # 01 Y:1999 | 01 | 1999 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $9,897 | $5,660 | Not Implemented |
GT0665 # 02 Y:1999 | 02 | 1999 | FILTER AND REUSE HYDRAULIC OIL | $2,625 | $3,500 | Not Implemented |
GT0665 # 03 Y:1999 | 03 | 1999 | MAINTAIN MACHINES TO REDUCE LEAKS | $6,500 | $5,000 | Not Implemented |
GT0665 # 04 Y:1999 | 04 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $213,845 | $700,000 | Not Implemented |
GT0665 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,023 | $54,672 | Not Implemented |
GT0665 # 06 Y:1999 | 06 | 1999 | USE POWER DURING OFF-PEAK PERIODS | $38,560 | $0 | Not Implemented |
GT0662 # 01 Y:1999 | 01 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,196 | $3,800 | Implemented |
GT0662 # 02 Y:1999 | 02 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $22,317 | $550 | Implemented |
GT0662 # 03 Y:1999 | 03 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $424,479 | $250,000 | Implemented |
GT0662 # 04 Y:1999 | 04 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $16,138 | $30,000 | Not Implemented |
GT0662 # 05 Y:1999 | 05 | 1999 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $68,343 | $60,000 | Implemented |
GT0662 # 06 Y:1999 | 06 | 1999 | RECOVER AND REUSE COOLING WATER | $85,620 | $30,000 | Implemented |
GT0662 # 07 Y:1999 | 07 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,775 | $0 | Not Implemented |
GT0662 # 08 Y:1999 | 08 | 1999 | COMBINE UTILITY METERS | $14,794 | $0 | Not Implemented |
GT0608 # 01 Y:1997 | 01 | 1997 | COMBINE UTILITY METERS | $8,120 | $18,860 | Implemented |
GT0608 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $426 | $6,227 | Implemented |
GT0608 # 03 Y:1997 | 03 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,260 | $4,000 | Implemented |
GT0608 # 04 Y:1997 | 04 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,317 | $3,510 | Implemented |
GT0608 # 05 Y:1997 | 05 | 1997 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $2,625 | $3,500 | Not Implemented |
GT0608 # 06 Y:1997 | 06 | 1997 | USE GRAVITY FEEDS WHEREVER POSSIBLE | $3,425 | $5,130 | Implemented |
GT0608 # 07 Y:1997 | 07 | 1997 | USE GRAVITY FEEDS WHEREVER POSSIBLE | $2,568 | $14,250 | Not Implemented |
GT0608 # 08 Y:1997 | 08 | 1997 | DISCONNECT BALLASTS | $552 | $84 | Implemented |
GT0608 # 09 Y:1997 | 09 | 1997 | MAINTAIN MACHINES TO REDUCE LEAKS | $6,500 | $5,000 | Not Implemented |