Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
219
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0662 # 02 Y:1999 | 02 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $22,317 | $550 | Implemented |
GT0662 # 03 Y:1999 | 03 | 1999 | $424,479 | $250,000 | Implemented | |
GT0662 # 04 Y:1999 | 04 | 1999 | $16,138 | $30,000 | Not Implemented | |
GT0662 # 05 Y:1999 | 05 | 1999 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $68,343 | $60,000 | Implemented |
GT0662 # 06 Y:1999 | 06 | 1999 | RECOVER AND REUSE COOLING WATER | $85,620 | $30,000 | Implemented |
GT0662 # 07 Y:1999 | 07 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,775 | $0 | Not Implemented |
GT0662 # 08 Y:1999 | 08 | 1999 | COMBINE UTILITY METERS | $14,794 | $0 | Not Implemented |
GT0608 # 01 Y:1997 | 01 | 1997 | COMBINE UTILITY METERS | $8,120 | $18,860 | Implemented |
GT0608 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $426 | $6,227 | Implemented |
GT0608 # 03 Y:1997 | 03 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,260 | $4,000 | Implemented |
GT0608 # 04 Y:1997 | 04 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,317 | $3,510 | Implemented |
GT0608 # 05 Y:1997 | 05 | 1997 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $2,625 | $3,500 | Not Implemented |
GT0608 # 06 Y:1997 | 06 | 1997 | USE GRAVITY FEEDS WHEREVER POSSIBLE | $3,425 | $5,130 | Implemented |
GT0608 # 07 Y:1997 | 07 | 1997 | USE GRAVITY FEEDS WHEREVER POSSIBLE | $2,568 | $14,250 | Not Implemented |
GT0608 # 08 Y:1997 | 08 | 1997 | DISCONNECT BALLASTS | $552 | $84 | Implemented |
GT0608 # 09 Y:1997 | 09 | 1997 | MAINTAIN MACHINES TO REDUCE LEAKS | $6,500 | $5,000 | Not Implemented |
GT0608 # 10 Y:1997 | 10 | 1997 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $2,500 | $9,400 | Implemented |
GT0601 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,440 | $12,710 | Implemented |
GT0601 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,643 | $350 | Implemented |
GT0601 # 03 Y:1996 | 03 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,579 | $2,000 | Not Implemented |
GT0601 # 04 Y:1996 | 04 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $45,800 | $10,000 | Not Implemented |
GT0601 # 05 Y:1996 | 05 | 1996 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $3,830 | $6,000 | Implemented |
GT0601 # 06 Y:1996 | 06 | 1996 | USE LESS WASTEFUL PACKAGING | $21,600 | $45,000 | Implemented |
GT0562 # 01 Y:1995 | 01 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $82,460 | $0 | Implemented |
GT0562 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $67,980 | $0 | Implemented |