Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0444 # 04 Y:2017 | 04 | 2017 | INSTALL SKYLIGHTS | $1,596 | $1,633 | Not Implemented |
AS0444 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,007 | $100 | Implemented |
AS0444 # 02 Y:2017 | 02 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,643 | $872 | Implemented |
AS0444 # 01 Y:2017 | 01 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $33,358 | $4,325 | Not Implemented |
LS0004 # 09 Y:2017 | 09 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $68 | $0 | Not Implemented |
LS0004 # 04 Y:2017 | 04 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $627 | $0 | Not Implemented |
LS0004 # 05 Y:2017 | 05 | 2017 | USE PHOTOCELL CONTROLS | $188 | $0 | Not Implemented |
LS0004 # 02 Y:2017 | 02 | 2017 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $6,311 | $0 | Not Implemented |
LS0004 # 01 Y:2017 | 01 | 2017 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $43,789 | $0 | Not Implemented |
LS0004 # 10 Y:2017 | 10 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $23 | $0 | Not Implemented |
LS0004 # 06 Y:2017 | 06 | 2017 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $110 | $0 | Not Implemented |
LS0004 # 03 Y:2017 | 03 | 2017 | MINIMIZE WATER USAGE | $2,256 | $0 | Not Implemented |
LS0004 # 08 Y:2017 | 08 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $203 | $0 | Not Implemented |
LS0004 # 07 Y:2017 | 07 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $444 | $0 | Not Implemented |
LS0004 # 11 Y:2017 | 11 | 2017 | PAY UTILITY BILLS ON TIME | $241 | $0 | Not Implemented |
MA0776 # 01 Y:2017 | 01 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $35,581 | $238,058 | Not Implemented |
MA0776 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,365 | $15,725 | Implemented |
MA0776 # 03 Y:2017 | 03 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $973 | $301 | Implemented |
WV0547 # 12 Y:2017 | 12 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $102 | $348 | Not Implemented |
WV0547 # 11 Y:2017 | 11 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $133 | $25 | Not Implemented |
WV0547 # 08 Y:2017 | 08 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $412 | $2,050 | Implemented |
WV0547 # 06 Y:2017 | 06 | 2017 | ADJUST BURNERS FOR EFFICIENT OPERATION | $970 | $4,600 | Implemented |
WV0547 # 05 Y:2017 | 05 | 2017 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,360 | $2,700 | Not Implemented |
WV0547 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,491 | $9,434 | Implemented |
WV0547 # 02 Y:2017 | 02 | 2017 | IMPROVE COMBUSTION CONTROL CAPABILITY | $7,947 | $25,500 | Not Implemented |