Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
163
matching recommendationsSIC | 321 | Flat Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0573 # 07 Y:2010 | 07 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $270 | $105 | Implemented |
AM0573 # 06 Y:2010 | 06 | 2010 | COMBINE UTILITY METERS | $1,310 | $1,250 | Not Implemented |
AM0573 # 05 Y:2010 | 05 | 2010 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,370 | $0 | Implemented |
AM0573 # 01 Y:2010 | 01 | 2010 | ADD ADDITIONAL PRODUCTION SHIFT | $18,420 | $0 | Not Implemented |
AM0573 # 02 Y:2010 | 02 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $17,800 | $3,915 | Implemented |
AM0573 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,360 | $500 | Implemented |
AM0573 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,750 | $685 | Implemented |
OK0769 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $98,641 | $246,228 | Not Implemented |
OK0769 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $788 | $1,922 | Implemented |
OK0769 # 05 Y:2008 | 05 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,911 | $4,475 | Implemented |
OK0769 # 02 Y:2008 | 02 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $18,368 | $731 | Not Implemented |
OK0769 # 07 Y:2008 | 07 | 2008 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $451,827 | $2,500,000 | Not Implemented |
OK0769 # 01 Y:2008 | 01 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $53,558 | $2,347 | Not Implemented |
OK0769 # 06 Y:2008 | 06 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,068 | $200 | Not Implemented |
LL0293 # 02 Y:2008 | 02 | 2008 | INSULATE BARE EQUIPMENT | $3,531 | $655 | Implemented |
LL0293 # 03 Y:2008 | 03 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,733 | $60 | Implemented |
LL0293 # 05 Y:2008 | 05 | 2008 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $889 | $45 | Implemented |
LL0293 # 01 Y:2008 | 01 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $37,156 | $56,346 | Not Implemented |
LL0293 # 04 Y:2008 | 04 | 2008 | USE PHOTOCELL CONTROLS | $1,073 | $60 | Implemented |
LL0293 # 07 Y:2008 | 07 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $436 | $501 | Not Implemented |
LL0293 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $819 | $360 | Implemented |
IA0407 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,719 | $38,791 | Implemented |
IA0407 # 06 Y:2007 | 06 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,084 | $12,025 | Implemented |
IA0407 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $132,474 | $185,735 | Not Implemented |
IA0407 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,098 | $4,794 | Implemented |