Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 3229 | Pressed And Blown Glass, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0533 # 11 Y:1994 | 11 | 1994 | CONVERT TO AQUEOUS CLEANING SYSTEM | $3,325 | $3,000 | Implemented |
TN0533 # 08 Y:1994 | 08 | 1994 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $34,098 | $45,100 | Implemented |
TN0533 # 07 Y:1994 | 07 | 1994 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $56,576 | $32,240 | Implemented |
TN0533 # 06 Y:1994 | 06 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,523 | $3,350 | Implemented |
TN0533 # 04 Y:1994 | 04 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,318 | $700 | Implemented |
TN0533 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $4,449 | $200 | Implemented |
TN0496 # 02 Y:1993 | 02 | 1993 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $3,057 | $0 | Implemented |
TN0496 # 07 Y:1993 | 07 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $603 | $0 | Implemented |
TN0496 # 05 Y:1993 | 05 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,353 | $4,000 | Implemented |
TN0496 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,000 | $820 | Implemented |
TN0496 # 03 Y:1993 | 03 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,105 | $1,254 | Implemented |
TN0363 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $125,794 | $1,200 | Implemented |
TN0364 # 05 Y:1989 | 05 | 1989 | CLOSE OFF UNNEEDED STEAM LINES | $3,036 | $0 | Implemented |
TN0364 # 04 Y:1989 | 04 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,471 | $800 | Implemented |
TN0364 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $139,595 | $0 | Implemented |
TN0363 # 08 Y:1989 | 08 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,085 | $600 | Implemented |
TN0363 # 07 Y:1989 | 07 | 1989 | INSTALL SET-BACK TIMERS | $2,215 | $0 | Implemented |
TN0363 # 06 Y:1989 | 06 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $6,829 | $21,293 | Implemented |
TN0363 # 05 Y:1989 | 05 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,789 | $7,480 | Implemented |
TN0363 # 04 Y:1989 | 04 | 1989 | USE MINIMUM STEAM OPERATING PRESSURE | $3,504 | $0 | Implemented |
TN0363 # 03 Y:1989 | 03 | 1989 | INSTALL STEAM TRAP | $8,302 | $3,450 | Implemented |
TN0363 # 02 Y:1989 | 02 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $57,307 | $379,000 | Implemented |