Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
62
matching recommendationsSIC | 3229 | Pressed And Blown Glass, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0143 # 09 Y:1998 | 09 | 1998 | DISCONNECT BALLASTS | $1,037 | $1,770 | Implemented |
WV0143 # 08 Y:1998 | 08 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $340 | $0 | Implemented |
WV0143 # 07 Y:1998 | 07 | 1998 | INSULATE BARE EQUIPMENT | $221 | $199 | Not Implemented |
WV0143 # 06 Y:1998 | 06 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $572 | $266 | Implemented |
WV0143 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,010 | $2,720 | Implemented |
WV0143 # 04 Y:1998 | 04 | 1998 | COVER OPEN TANKS | $6,458 | $522 | Not Implemented |
WV0143 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $77 | $82 | Not Implemented |
WV0143 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,672 | $0 | Implemented |
WV0143 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $276 | $281 | Implemented |
WV0142 # 10 Y:1998 | 10 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $960 | $100 | Implemented |
WV0142 # 11 Y:1998 | 11 | 1998 | $29,750 | $500 | Implemented | |
WV0142 # 09 Y:1998 | 09 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,076 | $11,000 | Not Implemented |
WV0142 # 08 Y:1998 | 08 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $139 | $126 | Implemented |
WV0142 # 07 Y:1998 | 07 | 1998 | INSULATE BARE EQUIPMENT | $3,358 | $1,330 | Implemented |
WV0142 # 06 Y:1998 | 06 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $51 | $88 | Implemented |
WV0142 # 05 Y:1998 | 05 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,509 | $605 | Not Implemented |
WV0142 # 04 Y:1998 | 04 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14 | $10 | Implemented |
WV0142 # 03 Y:1998 | 03 | 1998 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $152 | $316 | Not Implemented |
WV0142 # 02 Y:1998 | 02 | 1998 | COVER OPEN TANKS | $387 | $1,056 | Not Implemented |
WV0142 # 01 Y:1998 | 01 | 1998 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,491 | $1,400 | Not Implemented |
WV0141 # 07 Y:1998 | 07 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $166 | $40 | Implemented |
WV0141 # 05 Y:1998 | 05 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $3,479 | $677 | Not Implemented |
WV0141 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $198 | $152 | Implemented |
WV0141 # 03 Y:1998 | 03 | 1998 | INSULATE BARE EQUIPMENT | $5,488 | $910 | Implemented |
WV0141 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $92 | $85 | Not Implemented |