Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 3229 | Pressed And Blown Glass, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0533 # 11 Y:1994 | 11 | 1994 | CONVERT TO AQUEOUS CLEANING SYSTEM | $3,325 | $3,000 | Implemented |
TN0533 # 10 Y:1994 | 10 | 1994 | TREAT AND REUSE RINSE WATERS | $7,445 | $12,650 | Not Implemented |
TN0533 # 09 Y:1994 | 09 | 1994 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $18,473 | $5,000 | Not Implemented |
TN0533 # 08 Y:1994 | 08 | 1994 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $34,098 | $45,100 | Implemented |
TN0533 # 07 Y:1994 | 07 | 1994 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $56,576 | $32,240 | Implemented |
TN0533 # 06 Y:1994 | 06 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,523 | $3,350 | Implemented |
TN0533 # 05 Y:1994 | 05 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,300 | $0 | Not Implemented |
TN0533 # 04 Y:1994 | 04 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,318 | $700 | Implemented |
TN0533 # 03 Y:1994 | 03 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,344 | $1,680 | Not Implemented |
TN0533 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $4,449 | $200 | Implemented |
TN0533 # 01 Y:1994 | 01 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,262 | $4,455 | Not Implemented |
TN0496 # 03 Y:1993 | 03 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,105 | $1,254 | Implemented |
TN0496 # 07 Y:1993 | 07 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $603 | $0 | Implemented |
TN0496 # 06 Y:1993 | 06 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,150 | $0 | Not Implemented |
TN0496 # 05 Y:1993 | 05 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $1,353 | $4,000 | Implemented |
TN0496 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,000 | $820 | Implemented |
TN0496 # 02 Y:1993 | 02 | 1993 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $3,057 | $0 | Implemented |
TN0496 # 01 Y:1993 | 01 | 1993 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $153,224 | $275,000 | Not Implemented |
TN0363 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $125,794 | $1,200 | Implemented |
TN0364 # 06 Y:1989 | 06 | 1989 | INSTALL SET-BACK TIMERS | $3,442 | $10,900 | Not Implemented |
TN0364 # 05 Y:1989 | 05 | 1989 | CLOSE OFF UNNEEDED STEAM LINES | $3,036 | $0 | Implemented |
TN0364 # 04 Y:1989 | 04 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,471 | $800 | Implemented |
TN0364 # 03 Y:1989 | 03 | 1989 | USE MINIMUM STEAM OPERATING PRESSURE | $15,272 | $0 | Not Implemented |
TN0364 # 02 Y:1989 | 02 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $112,374 | $757,200 | Not Implemented |
TN0364 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $139,595 | $0 | Implemented |