Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
740
matching recommendationsSIC | 3231 | Products Of Purchased Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0303 # 10 Y:2001 | 10 | 2001 | EXPAND OPERATIONS INTO UNUSED SPACE | $280,143 | $6,204 | n/a |
UD0614 # 01 Y:2001 | 01 | 2001 | INCREASE USE OF AUTOMATION | $277,500 | $100,000 | Not Implemented |
UD0614 # 02 Y:2001 | 02 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $53,184 | $30,570 | Implemented |
UD0614 # 03 Y:2001 | 03 | 2001 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $11,618 | $23,000 | Not Implemented |
UD0614 # 04 Y:2001 | 04 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,036 | $0 | Not Implemented |
UD0614 # 05 Y:2001 | 05 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,252 | $0 | Implemented |
NC0185 # 01 Y:2000 | 01 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $637 | $800 | Implemented |
NC0185 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $537 | $1,700 | Not Implemented |
NC0185 # 03 Y:2000 | 03 | 2000 | DISCONNECT BALLASTS | $441 | $500 | Implemented |
NC0185 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,808 | $4,950 | Not Implemented |
NC0185 # 05 Y:2000 | 05 | 2000 | USE OPTIMUM THICKNESS INSULATION | $4,274 | $1,200 | Implemented |
NC0185 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,584 | $50 | Implemented |
NC0185 # 07 Y:2000 | 07 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $112 | $90 | Not Implemented |
NC0185 # 08 Y:2000 | 08 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,750 | $1,000 | Implemented |
NC0185 # 09 Y:2000 | 09 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $143,125 | $27,000 | Not Implemented |
CO0460 # 01 Y:2000 | 01 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,940 | $7,500 | Implemented |
CO0460 # 02 Y:2000 | 02 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $540 | $250 | Not Implemented |
CO0460 # 03 Y:2000 | 03 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $530 | $750 | Not Implemented |
CO0460 # 04 Y:2000 | 04 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $430 | $670 | Implemented |
CO0460 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $240 | $600 | Implemented |
CO0460 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $200 | $210 | Implemented |
CO0460 # 07 Y:2000 | 07 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $200 | $0 | Not Implemented |
CO0460 # 08 Y:2000 | 08 | 2000 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $166,400 | $40,000 | Implemented |
CO0460 # 09 Y:2000 | 09 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $72,730 | $122,000 | Implemented |
UF0243 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,393 | $0 | Implemented |