Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
740
matching recommendationsSIC | 3231 | Products Of Purchased Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0725 # 02 Y:2017 | 02 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $27,250 | $15,000 | Implemented |
AM0725 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,880 | $1,000 | Implemented |
AM0725 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,640 | $13,720 | Implemented |
AM0725 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,890 | $2,060 | Implemented |
AM0725 # 06 Y:2017 | 06 | 2017 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $730 | $0 | Implemented |
AM0725 # 07 Y:2017 | 07 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $350 | $270 | Implemented |
AM0725 # 08 Y:2017 | 08 | 2017 | INSTALL OCCUPANCY SENSORS | $310 | $130 | Implemented |
UA0170 # 01 Y:2016 | 01 | 2016 | INSULATE BARE EQUIPMENT | $40,043 | $13,993 | Not Implemented |
UA0170 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,349 | $27,272 | Implemented |
UA0170 # 03 Y:2016 | 03 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,746 | $0 | Not Implemented |
UA0170 # 04 Y:2016 | 04 | 2016 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,881 | $7,219 | Implemented |
UA0170 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,533 | $1,115 | Implemented |
UA0170 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,100 | $350 | Not Implemented |
UA0170 # 07 Y:2016 | 07 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $496 | $870 | Implemented |
OK0945 # 04 Y:2016 | 04 | 2016 | INSULATE BARE EQUIPMENT | $14,580 | $10,000 | Not Implemented |
OK0945 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,559 | $26,380 | Implemented |
OK0945 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,229 | $0 | Not Implemented |
OK0945 # 01 Y:2016 | 01 | 2016 | OPTIMIZE PLANT POWER FACTOR | $23,818 | $29,535 | Not Implemented |
WV0525 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,826 | $10,031 | Implemented |
WV0525 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,504 | $362 | Implemented |
WV0525 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,290 | $6,270 | Implemented |
WV0525 # 04 Y:2016 | 04 | 2016 | INSTALL SET-BACK TIMERS | $3,716 | $4,223 | Not Implemented |
WV0525 # 05 Y:2016 | 05 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,568 | $1,114 | Not Implemented |
WV0525 # 06 Y:2016 | 06 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $2,799 | $5,000 | Not Implemented |
WV0525 # 07 Y:2016 | 07 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,575 | $4,088 | Implemented |