Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 3231 | Products Of Purchased Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0616 # 10 Y:2018 | 10 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,190 | $500 | Not Implemented |
NC0616 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,771 | $43,490 | Implemented |
NC0616 # 02 Y:2018 | 02 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,695 | $225 | Implemented |
NC0616 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $505 | $50 | Implemented |
NC0616 # 04 Y:2018 | 04 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,380 | $20,000 | Not Implemented |
NC0616 # 05 Y:2018 | 05 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,999 | $100 | Implemented |
NC0616 # 06 Y:2018 | 06 | 2018 | REDESIGN PROCESS | $7,804 | $10,000 | Not Implemented |
NC0616 # 07 Y:2018 | 07 | 2018 | INSTALL SENSORS TO DETECT DEFECTS | $112,500 | $150,000 | Implemented |
NC0616 # 08 Y:2018 | 08 | 2018 | REDESIGN PROCESS | $36,741 | $2,500 | Implemented |
NC0616 # 09 Y:2018 | 09 | 2018 | AVOID REWINDING MOTORS MORE THAN TWICE | $2,586 | $5,865 | Implemented |
NC0374 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $53,915 | $100,000 | Implemented |
NC0374 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,040 | $7,000 | Implemented |
NC0374 # 04 Y:2008 | 04 | 2008 | REDESIGN PROCESS | $11,653 | $22,000 | Not Implemented |
NC0374 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,977 | $100 | Implemented |
NC0374 # 02 Y:2008 | 02 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,372 | $18,000 | Implemented |
NC0374 # 01 Y:2008 | 01 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $32,923 | $63,000 | Implemented |
NC0185 # 07 Y:2000 | 07 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $112 | $90 | Not Implemented |
NC0185 # 09 Y:2000 | 09 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $143,125 | $27,000 | Not Implemented |
NC0185 # 08 Y:2000 | 08 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,750 | $1,000 | Implemented |
NC0185 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,584 | $50 | Implemented |
NC0185 # 05 Y:2000 | 05 | 2000 | USE OPTIMUM THICKNESS INSULATION | $4,274 | $1,200 | Implemented |
NC0185 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,808 | $4,950 | Not Implemented |
NC0185 # 03 Y:2000 | 03 | 2000 | DISCONNECT BALLASTS | $441 | $500 | Implemented |
NC0185 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $537 | $1,700 | Not Implemented |
NC0185 # 01 Y:2000 | 01 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $637 | $800 | Implemented |