Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2018 |
Principal Product | Mirrors and glass |
NAICS | 327215 - Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231 - Products Of Purchased Glass |
Sales | $50,000,000-$100,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 165,000 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 4,800 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $224,243 | 3,150,173 | kWh | $0.07 |
Electricity Demand | $53,260 | 12,275 | kW-months/year | $4.34 |
Natural Gas | $24,847 | 2,863 | MMBtu | $8.68 |
TOTAL ENERGY COSTS | $302,350 | |||
RECOMMENDED SAVINGS* | $205,171 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $169,797 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,771 Cost: $43,490 |
$11,715 | 164,533 | $2,056 | 460 | - | - | - | - | - | - | - | - | - | - |
$11,715 164,533 kWh |
$2,056 460 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,695 Cost: $225 |
$1,659 | 23,302 | $261 | 58 | - | - | $(-180) | - | $(-45) | - | - | - | - | - |
$1,659 23,302 kWh |
$261 58 kW-months/year |
- - MMBtu |
$(-180) - $ |
$(-45) - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $505 Cost: $50 |
$435 | 6,114 | $70 | 16 | - | - | - | - | - | - | - | - | - | - |
$435 6,114 kWh |
$70 16 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $12,380 Cost: $20,000 |
$10,701 | 150,298 | $1,679 | 376 | - | - | - | - | - | - | - | - | - | - |
$10,701 150,298 kWh |
$1,679 376 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $1,999 Cost: $100 |
$1,999 | 28,080 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,999 28,080 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.5194 REDESIGN PROCESS |
Savings: $7,804 Cost: $10,000 |
- | - | - | - | $304 | 35 | - | - | - | - | $7,500 | - | - | - |
- - kWh |
- - kW-months/year |
$304 35 MMBtu |
- - $ |
- - $ |
$7,500 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $112,500 Cost: $150,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $112,500 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
$112,500 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.5194 REDESIGN PROCESS |
Savings: $36,741 Cost: $2,500 |
$(-656) | (-9,216) | $(-103) | (-23) | - | - | - | - | - | - | $37,500 | - | - | - |
$(-656) (-9,216) kWh |
$(-103) (-23) kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$37,500 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4154 AVOID REWINDING MOTORS MORE THAN TWICE |
Savings: $2,586 Cost: $5,865 |
$2,236 | 31,406 | $350 | 78 | - | - | - | - | - | - | - | - | - | - |
$2,236 31,406 kWh |
$350 78 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $15,190 Cost: $500 |
$15,190 | - | - | - | - | - | - | - | - | - | - | - | - | - |
$15,190 - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $205,171 Cost: $232,730 |
$43,279 | 394,517 | $4,313 | 965 | $304 | 35 | $(-180) | - | $(-45) | - | $45,000 | - | $112,500 | - | $43,279 394,517 kWh |
$4,313 965 kW-months/year |
$304 35 MMBtu |
$(-180) - $ |
$(-45) - $ |
$45,000 - $ |
$112,500 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $169,797 Cost: $202,230 |
$17,388 | 244,219 | $2,634 | 589 | - | - | $(-180) | - | $(-45) | - | $37,500 | - | $112,500 | - | $17,388 244,219 kWh |
$2,634 589 kW-months/year |
- - MMBtu |
$(-180) - $ |
$(-45) - $ |
$37,500 - $ |
$112,500 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Increase in Production |