Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20

matching recommendations
Reset
SIC 3231 Products Of Purchased Glass
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0122 # 03 Y:1997 03 1997 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $831 $1,000 Not Implemented
NC0122 # 12 Y:1997 12 1997 EXPAND OPERATIONS INTO UNUSED SPACE $9,330 $3,330 Implemented
NC0122 # 11 Y:1997 11 1997 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $36,445 $100,000 Not Implemented
NC0122 # 10 Y:1997 10 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,157 $400 Implemented
NC0122 # 09 Y:1997 09 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $27,463 $13,500 Not Implemented
NC0122 # 08 Y:1997 08 1997 TREAT AND REUSE RINSE WATERS $12,101 $2,500 Not Implemented
NC0122 # 07 Y:1997 07 1997 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $973 $1,500 Implemented
NC0122 # 06 Y:1997 06 1997 REPLACE BOILER $8,881 $36,000 Not Implemented
NC0122 # 05 Y:1997 05 1997 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,108 $3,500 Not Implemented
NC0122 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,262 $600 Not Implemented
NC0122 # 02 Y:1997 02 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $884 $468 Not Implemented
NC0122 # 01 Y:1997 01 1997 USE OPTIMUM THICKNESS INSULATION $1,591 $647 Not Implemented
DS0090 # 01 Y:1997 01 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,097 $1,800 Implemented
DS0090 # 08 Y:1997 08 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $70,200 $65,000 Implemented
DS0090 # 07 Y:1997 07 1997 REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS $13,750 $19,000 Implemented
DS0090 # 06 Y:1997 06 1997 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $13,735 $9,500 Implemented
DS0090 # 05 Y:1997 05 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $10,196 $32,400 Not Implemented
DS0090 # 04 Y:1997 04 1997 UTILIZE A LESS EXPENSIVE COOLING METHOD $16,937 $20,000 Implemented
DS0090 # 03 Y:1997 03 1997 COVER OPEN TANKS $634 $242 Not Implemented
DS0090 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,210 $1,910 Implemented