Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20
matching recommendationsSIC | 3231 | Products Of Purchased Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0122 # 03 Y:1997 | 03 | 1997 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $831 | $1,000 | Not Implemented |
NC0122 # 12 Y:1997 | 12 | 1997 | EXPAND OPERATIONS INTO UNUSED SPACE | $9,330 | $3,330 | Implemented |
NC0122 # 11 Y:1997 | 11 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $36,445 | $100,000 | Not Implemented |
NC0122 # 10 Y:1997 | 10 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,157 | $400 | Implemented |
NC0122 # 09 Y:1997 | 09 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $27,463 | $13,500 | Not Implemented |
NC0122 # 08 Y:1997 | 08 | 1997 | TREAT AND REUSE RINSE WATERS | $12,101 | $2,500 | Not Implemented |
NC0122 # 07 Y:1997 | 07 | 1997 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $973 | $1,500 | Implemented |
NC0122 # 06 Y:1997 | 06 | 1997 | REPLACE BOILER | $8,881 | $36,000 | Not Implemented |
NC0122 # 05 Y:1997 | 05 | 1997 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,108 | $3,500 | Not Implemented |
NC0122 # 04 Y:1997 | 04 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,262 | $600 | Not Implemented |
NC0122 # 02 Y:1997 | 02 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $884 | $468 | Not Implemented |
NC0122 # 01 Y:1997 | 01 | 1997 | USE OPTIMUM THICKNESS INSULATION | $1,591 | $647 | Not Implemented |
DS0090 # 01 Y:1997 | 01 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,097 | $1,800 | Implemented |
DS0090 # 08 Y:1997 | 08 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $70,200 | $65,000 | Implemented |
DS0090 # 07 Y:1997 | 07 | 1997 | REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS | $13,750 | $19,000 | Implemented |
DS0090 # 06 Y:1997 | 06 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $13,735 | $9,500 | Implemented |
DS0090 # 05 Y:1997 | 05 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $10,196 | $32,400 | Not Implemented |
DS0090 # 04 Y:1997 | 04 | 1997 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $16,937 | $20,000 | Implemented |
DS0090 # 03 Y:1997 | 03 | 1997 | COVER OPEN TANKS | $634 | $242 | Not Implemented |
DS0090 # 02 Y:1997 | 02 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,210 | $1,910 | Implemented |