Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 325 | Structural Clay Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0325 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $114 | $120 | Not Implemented |
LL0325 # 05 Y:2010 | 05 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $803 | $623 | Not Implemented |
LL0325 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,019 | $1,265 | Implemented |
LL0325 # 07 Y:2010 | 07 | 2010 | USE PHOTOCELL CONTROLS | $39 | $30 | Not Implemented |
LL0325 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,166 | $595 | Not Implemented |
LL0325 # 02 Y:2010 | 02 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,692 | $30 | Implemented |
LL0325 # 01 Y:2010 | 01 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $40,139 | $3,000 | Implemented |
MS0271 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $790 | $1,539 | Not Implemented |
MS0271 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $888 | $250 | Not Implemented |
MS0271 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,569 | $3,249 | Not Implemented |
MS0271 # 02 Y:2005 | 02 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $1,726 | $3,000 | Not Implemented |
MS0271 # 01 Y:2005 | 01 | 2005 | USE OPTIMUM THICKNESS INSULATION | $46,503 | $3,038 | Not Implemented |
MS0149 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,504 | $2,060 | Implemented |
MS0149 # 04 Y:1999 | 04 | 1999 | USE OPTIMUM THICKNESS INSULATION | $15,653 | $9,593 | Not Implemented |
MS0149 # 02 Y:1999 | 02 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $74 | $119 | Not Implemented |
MS0149 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $790 | $263 | Implemented |
MS0097 # 06 Y:1997 | 06 | 1997 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $26,125 | $32,289 | Implemented |
MS0097 # 05 Y:1997 | 05 | 1997 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $5,931 | $1,158 | Implemented |
MS0097 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,896 | $8,648 | Implemented |
MS0097 # 03 Y:1997 | 03 | 1997 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $828 | $482 | Not Implemented |
MS0097 # 02 Y:1997 | 02 | 1997 | OPTIMIZE PLANT POWER FACTOR | $4,746 | $1,326 | Implemented |
MS0097 # 01 Y:1997 | 01 | 1997 | USE OPTIMUM THICKNESS INSULATION | $78,996 | $81,321 | Not Implemented |
MS0012 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,294 | $2,130 | Not Implemented |
MS0012 # 04 Y:1994 | 04 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $29,988 | $15,000 | Not Implemented |
MS0012 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $342 | $700 | Not Implemented |