Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
268
matching recommendationsSIC | 3251 | Brick And Structural Clay Tile |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0512 # 03 Y:2015 | 03 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $4,536 | $20,300 | Not Implemented |
WV0512 # 06 Y:2015 | 06 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,537 | $80 | Implemented |
WV0512 # 09 Y:2015 | 09 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $762 | $554 | Implemented |
OK0839 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,540 | $0 | Implemented |
OK0839 # 10 Y:2013 | 10 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $80,680 | $63,370 | Not Implemented |
OK0839 # 08 Y:2013 | 08 | 2013 | INSTALL SET-BACK TIMERS | $921 | $1,630 | Not Implemented |
OK0839 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $667 | $3,677 | Not Implemented |
OK0839 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,494 | $33,218 | Implemented |
OK0839 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $506 | $3,114 | Not Implemented |
OK0839 # 12 Y:2013 | 12 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,901 | $4,994 | Not Implemented |
OK0839 # 16 Y:2013 | 16 | 2013 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $35,380 | $0 | Not Implemented |
OK0839 # 11 Y:2013 | 11 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $32,511 | $25,606 | Implemented |
OK0839 # 14 Y:2013 | 14 | 2013 | INSULATE BARE EQUIPMENT | $1,275 | $912 | Not Implemented |
OK0839 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,395 | $1,750 | Implemented |
OK0839 # 13 Y:2013 | 13 | 2013 | OPTIMIZE PLANT POWER FACTOR | $12,090 | $11,638 | Implemented |
OK0839 # 09 Y:2013 | 09 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $873 | $490 | Implemented |
OK0839 # 15 Y:2013 | 15 | 2013 | INSULATE BARE EQUIPMENT | $2,900 | $4,158 | Not Implemented |
OK0839 # 07 Y:2013 | 07 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,708 | $5,684 | Implemented |
OK0839 # 01 Y:2013 | 01 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,514 | $27,500 | Implemented |
AM0619 # 03 Y:2012 | 03 | 2012 | USE SYNTHETIC LUBRICANT | $2,900 | $0 | Not Implemented |
AM0619 # 02 Y:2012 | 02 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,470 | $0 | Implemented |
AM0619 # 07 Y:2012 | 07 | 2012 | PAY UTILITY BILLS ON TIME | $402 | $0 | Implemented |
AM0619 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,410 | $60 | Not Implemented |
AM0619 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,105 | $512 | Not Implemented |
AM0619 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,055 | $500 | Implemented |