Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
138
matching recommendationsSIC | 3253 | Ceramic Wall And Floor Tile |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0579 # 05 Y:2010 | 05 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $12,300 | $2,500 | Not Implemented |
AM0579 # 06 Y:2010 | 06 | 2010 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $1,700,000 | $0 | Not Implemented |
AM0579 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,550 | $1,000 | Not Implemented |
AM0579 # 08 Y:2010 | 08 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,415 | $500 | Not Implemented |
AM0579 # 09 Y:2010 | 09 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,140 | $12,387 | Not Implemented |
AM0579 # 10 Y:2010 | 10 | 2010 | USE SYNTHETIC LUBRICANT | $1,960 | $0 | Not Implemented |
AM0579 # 11 Y:2010 | 11 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,320 | $900 | Not Implemented |
OR0526 # 01 Y:2007 | 01 | 2007 | INSTALL SENSORS TO DETECT DEFECTS | $371,000 | $1,113,000 | Not Implemented |
OR0526 # 02 Y:2007 | 02 | 2007 | MODIFY WORKLOAD | $162,000 | $23,000 | Not Implemented |
OR0526 # 03 Y:2007 | 03 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $70,000 | $48,000 | Not Implemented |
OR0526 # 04 Y:2007 | 04 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,200 | $30,000 | Implemented |
OR0526 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,600 | $2,600 | Implemented |
OR0526 # 06 Y:2007 | 06 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $8,800 | $800 | Not Implemented |
OR0526 # 07 Y:2007 | 07 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,400 | $3,800 | Implemented |
SF0296 # 01 Y:2004 | 01 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $850 | $282 | Implemented |
SF0296 # 02 Y:2004 | 02 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,781 | $4,375 | Implemented |
SF0296 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,936 | $3,085 | Not Implemented |
SF0296 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $2,262 | $2,760 | Not Implemented |
SF0296 # 05 Y:2004 | 05 | 2004 | USE PHOTOCELL CONTROLS | $2,058 | $2,880 | Not Implemented |
SF0296 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,715 | $2,638 | Implemented |
SF0296 # 07 Y:2004 | 07 | 2004 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $753 | $1,520 | Implemented |
SF0296 # 08 Y:2004 | 08 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,293 | $5,681 | Not Implemented |
SF0296 # 09 Y:2004 | 09 | 2004 | USE PHOTOCELL CONTROLS | $1,017 | $3,059 | Implemented |
SF0296 # 10 Y:2004 | 10 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $14,141 | $36,000 | Not Implemented |
UL0241 # 01 Y:2000 | 01 | 2000 | OPTIMIZE PLANT POWER FACTOR | $24,726 | $16,605 | Implemented |