Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

127

matching recommendations
Reset
SIC 3253 Ceramic Wall And Floor Tile
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0526 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,600 $2,600 Implemented
OR0526 # 06 Y:2007 06 2007 UPGRADE CONTROLS ON COMPRESSORS $8,800 $800 Not Implemented
OR0526 # 07 Y:2007 07 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,400 $3,800 Implemented
SF0296 # 01 Y:2004 01 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $850 $282 Implemented
SF0296 # 02 Y:2004 02 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,781 $4,375 Implemented
SF0296 # 03 Y:2004 03 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,936 $3,085 Not Implemented
SF0296 # 04 Y:2004 04 2004 USE PHOTOCELL CONTROLS $2,262 $2,760 Not Implemented
SF0296 # 05 Y:2004 05 2004 USE PHOTOCELL CONTROLS $2,058 $2,880 Not Implemented
SF0296 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,715 $2,638 Implemented
SF0296 # 07 Y:2004 07 2004 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $753 $1,520 Implemented
SF0296 # 08 Y:2004 08 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,293 $5,681 Not Implemented
SF0296 # 09 Y:2004 09 2004 USE PHOTOCELL CONTROLS $1,017 $3,059 Implemented
SF0296 # 10 Y:2004 10 2004 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $14,141 $36,000 Not Implemented
UL0241 # 01 Y:2000 01 2000 OPTIMIZE PLANT POWER FACTOR $24,726 $16,605 Implemented
UL0241 # 02 Y:2000 02 2000 INSULATE BARE EQUIPMENT $34,297 $19,628 Not Implemented
UL0241 # 03 Y:2000 03 2000 $57,400 $38,400 Not Implemented
UL0241 # 04 Y:2000 04 2000 $6,583 $30,160 Not Implemented
AR0168 # 01 Y:1999 01 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,016 $608 Implemented
AR0168 # 02 Y:1999 02 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $223 $0 Implemented
AR0168 # 03 Y:1999 03 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $11,649 $7,750 Not Implemented
AR0168 # 04 Y:1999 04 1999 $21,008 $100 Not Implemented
WV0136 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,626 $10,375 Implemented
WV0136 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,603 $720 Not Implemented
WV0136 # 03 Y:1998 03 1998 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $777 $3,870 Not Implemented
WV0136 # 04 Y:1998 04 1998 RECOVER WASTE HEAT FROM EQUIPMENT $5,705 $1,225 Not Implemented