Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3262 | Vitreous China Table & Kitchenware |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0441 # 02 Y:2012 | 02 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $78,225 | $74,340 | Not Implemented |
WV0441 # 15 Y:2012 | 15 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,137 | $1,063 | Implemented |
WV0441 # 14 Y:2012 | 14 | 2012 | IMPROVE LUBRICATION PRACTICES | $2,709 | $3,400 | Not Implemented |
WV0441 # 13 Y:2012 | 13 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,782 | $0 | Implemented |
WV0441 # 12 Y:2012 | 12 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,825 | $12,850 | Not Implemented |
WV0441 # 11 Y:2012 | 11 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,115 | $3,000 | Not Implemented |
WV0441 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,022 | $9,275 | Implemented |
WV0441 # 09 Y:2012 | 09 | 2012 | OPTIMIZE PLANT POWER FACTOR | $10,618 | $46,340 | Not Implemented |
WV0441 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,024 | $37,887 | Implemented |
WV0441 # 07 Y:2012 | 07 | 2012 | INSULATE BARE EQUIPMENT | $20,023 | $6,777 | Not Implemented |
WV0441 # 06 Y:2012 | 06 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $38,793 | $10,750 | Implemented |
WV0441 # 05 Y:2012 | 05 | 2012 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $49,557 | $11,000 | Implemented |
WV0441 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $64,675 | $91,200 | Implemented |
WV0441 # 03 Y:2012 | 03 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $73,647 | $33,378 | Implemented |
WV0441 # 01 Y:2012 | 01 | 2012 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $200,857 | $610,000 | Not Implemented |
WV0212 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,955 | $540 | Implemented |
WV0212 # 12 Y:2001 | 12 | 2001 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $16,848 | $750 | Implemented |
WV0212 # 11 Y:2001 | 11 | 2001 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $20,054 | $1,307 | Implemented |
WV0212 # 10 Y:2001 | 10 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $480 | $100 | Implemented |
WV0212 # 09 Y:2001 | 09 | 2001 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $4,019 | $5,330 | Implemented |
WV0212 # 08 Y:2001 | 08 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,438 | $3,538 | Not Implemented |
WV0212 # 07 Y:2001 | 07 | 2001 | REPLACE BOILER | $17,262 | $9,690 | Not Implemented |
WV0212 # 06 Y:2001 | 06 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,940 | $1,885 | Not Implemented |
WV0212 # 05 Y:2001 | 05 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,806 | $480 | Implemented |
WV0212 # 04 Y:2001 | 04 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,007 | $500 | Not Implemented |